Neurological and neuropsychological examination and outcome after use of an intra-aortic filter device during cardiac surgery.

Cerebral embolization of particles after cardiac surgery is frequently associated with neurological deficits. Aortic crossclamp manipulation seems to be the most significant cause of emboli release during cardiac surgery. The goal of this study was to demonstrate whether the use of an intra-aortic f...

Descripción completa

Detalles Bibliográficos
Publicado en:Perfusion Vol. 18; pp. 55 - 61
Autores principales: Eifert S, Reichenspurner H, Pfefferkorn T, Baur B, von Schlippenbach C, Mayer TE, Hamann G, Reichart B
Formato: pictorial research tables/charts Journal Article
Publicado: Sage Publications, Ltd. Jan2003 Supplement
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106705611&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106705611
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        02676591
        31J
      jtl: Perfusion
      issn: 02676591
      maglogo: N
    pubinfo:
      dt: Jan2003 Supplement
      vid: 18
      pid: 33180
      pub: Sage Publications, Ltd.
      place: <Blank>
    artinfo:
      ui:
        106705611
        2004037162
        10.1191/0267659103pf628oa
        NLM12708766
        106705611
      ppf: 55
      ppct: 6
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Neurological and neuropsychological examination and outcome after use of an intra-aortic filter device during cardiac surgery.
      aug:
        au:
          Eifert S
          Reichenspurner H
          Pfefferkorn T
          Baur B
          von Schlippenbach C
          Mayer TE
          Hamann G
          Reichart B
        affil: Department of Cardiac Surgery, University Hospital Munich Grosshadern, Germany; Sandra.Eifert@hch.med.uni-muenchen.de
      sug:
        subj:
          Cardiac Surgery Evaluation
          Cardiac Surgery Methods
          Cognition Evaluation
          Coronary Artery Bypass
          Descriptive Statistics
          Germany
          Hemodynamics Evaluation
          Magnetic Resonance Imaging
          Microscopy
          Middle Age
          Paired T-Tests
          Treatment Outcomes Evaluation
          Wilcoxon Rank Sum Test
          Human
          Middle Aged: 45-64 years
      ab: Cerebral embolization of particles after cardiac surgery is frequently associated with neurological deficits. Aortic crossclamp manipulation seems to be the most significant cause of emboli release during cardiac surgery. The goal of this study was to demonstrate whether the use of an intra-aortic filter device has an effect on the magnet resonance imaging (MRI) and functional neurological outcome. Twenty-four patients undergoing cardiosurgical procedures using cardiopulmonary bypass (CPB) were selected: coronary artery bypass graft (CABG) surgery (n = 17), aortic valve replacement (AVR) surgery (n = 4) or combined procedures (n = 3). Patients were evaluated by diffusion weighted MRI of the brain, neurological examination and neuropsychological assessment regarding alertness as well as divided and selective attention before and five to seven days after surgery. The patients were divided into two groups. In group I, 12 patients received a filter through a modified 24 F arterial cannula immediately before the aortic crossclamp was released. Filters remained in the aorta until CPB was discontinued. Intraoperatively, bilateral middle cerebral artery transcranial Doppler (TCD) was monitored at baseline, at the beginning of CPB, at a timepoint when the aorta was crossclamped, when the filter was inserted and while the crossclamp was switched to partial clamping until the CPB was discontinued. TCD was used for detection of microembolic signals (MES). The captured material in the filter was examined histologically. Twelve patients served as controls without aortic filtration (group II). The MRI of the brain did not show any diffusion alterations in either group before or after surgery. No patient developed a focal neurological deficit or stroke. Intraoperative quantitative MES detection revealed a four to tenfold increase in patients of group I compared with group II (5-6 versus 0.5-1 MES/min) during the filter dwell time. There was no consistent pattern regarding the neurobehavioural sequelae. Filters showed arteriosclerotic debris in 75% of the patients. The use of the intra-aortic filter device did not show a positive effect on neurological, neuroradiographical and neuropsychological outcomes. The increase of the MES rate in group I patients may be due to microbubbles generated as microcavitations by the filter or the aortic filter cannula. The intra-aortic filter was able to capture atheromatous material in 75% of the patients.
      pubtype: Academic Journal
      doctype:
        pictorial
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N