Chronic experiences with a single lead dual chamber implantable cardioverter defibrillator system.

Monitoring of atrial rhythm in patients implanted with ICDs may improve accuracy in identifying supraventricular arrhythmias and, therefore, prevent inappropriate therapies. Since difficulties were found in dual chamber ICDs with separate leads, a new designed single lead dual chamber ICD system was...

Descripción completa

Detalles Bibliográficos
Publicado en:Pacing & Clinical Electrophysiology Vol. 26; no. 10; pp. 1937 - 1944
Autores principales: Niehaus M, De Sousa M, Klein G, Korte T, Pfeiffer D, Walles T, Raymondos K, Tebbenjohanns J
Formato: diagnostic images pictorial research tables/charts tracings Journal Article
Publicado: Wiley-Blackwell Oct2003
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106749690&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106749690
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01478389
        4F8
      jtl: Pacing & Clinical Electrophysiology
      issn: 01478389
      maglogo: Y
    pubinfo:
      dt: Oct2003
      vid: 26
      iid: 10
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        106749690
        106749690
        2004100113
        10.1046/j.1460-9592.2003.00299.x
        NLM14516332
        106749690
      ppf: 1937
      ppct: 7
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Chronic experiences with a single lead dual chamber implantable cardioverter defibrillator system.
      aug:
        au:
          Niehaus M
          De Sousa M
          Klein G
          Korte T
          Pfeiffer D
          Walles T
          Raymondos K
          Tebbenjohanns J
        affil: Dept of Cardiology and Angiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany; niehaus.michael@MH-Hannover.de
      sug:
        subj:
          Arrhythmia, Ventricular Therapy
          Defibrillators, Implantable Standards
          Electrodes, Implanted Standards
          Aged
          Atrial Fibrillation Diagnosis
          Atrial Flutter Diagnosis
          Descriptive Statistics
          Electrodes, Implanted Trends
          Female
          Fisher's Exact Test
          Male
          Tachycardia, Ventricular Diagnosis
          Tachycardia, Ventricular Therapy
          Unpaired T-Tests
          Ventricular Fibrillation Diagnosis
          Ventricular Fibrillation Therapy
          Funding Source
          Human
          Aged: 65+ years
          Female
          Male
      ab: Monitoring of atrial rhythm in patients implanted with ICDs may improve accuracy in identifying supraventricular arrhythmias and, therefore, prevent inappropriate therapies. Since difficulties were found in dual chamber ICDs with separate leads, a new designed single lead dual chamber ICD system was tested. Twenty-five patients implanted with a Deikos A+ (single coil defibrillation lead with two atrial sensing rings combined with a dual chamber ICD with a high amplifying atrial channel) were tested. Atrial and ventricular signals were analyzed during sinus rhythm (SR) and sinus tachycardias (STs), atrial flutter and AF, and VT or VF. Follow-ups were performed after 1, 3, 6, 9, and 12 months after implantation. Analysis of EGM amplitudes of stored episodes revealed that atrial signals during atrial flutter (2.1 +/- 0.51 mV) were comparable to those of ST (2.2 +/- 0.5 mV). Atrial amplitudes during AF were significantly lower (0.81 +/- 0.5 mV, P<0.01). During VF atrial 'sinus' signals (2 +/- 0.8 mV) were stable. Ventricular parameters did not differ from a standard ICD lead; defibrillation threshold was 11.4 +/- 4.5 J (16 patients). During intraoperative and prehospital discharge measurements, 97.1% of SR-P waves and 99.2% of atrial flutter waves were detected correctly. In AF 91.11% of atrial signals were detected. Analysis of 505 stored episodes showed that 96.8% of ST and 100% of atrial flutter and 100% of AF episodes have been classified correctly and no underdetection of VT/VF was found. The first experiences with the new VDD-ICD system show an increase of the specificity to detect ventricular tachycardias to a level comparable to dual chamber ICDs with two leads. The reliability of this system has to be proven in a prospective randomized study.
      pubtype: Academic Journal
      doctype:
        diagnostic images
        pictorial
        research
        tables/charts
        tracings
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N