Comparison of electrically evoked whole-nerve action potential and electrically evoked auditory brainstem response thresholds in nucleus CI24R cochlear implant recipients.

In this study, differences between electrically evoked whole-nerve action potential (EAP) and electrically evoked auditory brainstem response (EABR) measurements within Nucleus CI24R cochlear implant recipients were evaluated. Precurved modiolus-hugging internal electrode arrays, such as the CI24R,...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of the American Academy of Audiology Vol. 13; no. 8; pp. 416 - 430
Autores principales: Hay-McCutcheon MJ, Brown CJ, Clay KS, Seyle K
Formato: CEU exam questions research tables/charts Journal Article
Publicado: Thieme Medical Publishing Inc. Sep2002
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106796209&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106796209
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        10500545
        9OC
      jtl: Journal of the American Academy of Audiology
      issn: 10500545
      maglogo: Y
    pubinfo:
      dt: Sep2002
      vid: 13
      iid: 8
      pid: 2811
      pub: Thieme Medical Publishing Inc.
      place: New York, New York
    artinfo:
      ui:
        106796209
        106796209
        2003016471
        10.1055/s-0040-1716005
        NLM12371659
        106796209
      ppf: 416
      ppct: 14
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Comparison of electrically evoked whole-nerve action potential and electrically evoked auditory brainstem response thresholds in nucleus CI24R cochlear implant recipients.
      aug:
        au:
          Hay-McCutcheon MJ
          Brown CJ
          Clay KS
          Seyle K
        affil: Department of Speech Pathology and Audiology, 119 Wendell Johnson Speech and Hearing Center, Iowa City, IA 52242
      sug:
        subj:
          Cochlear Implant
          Evoked Potentials, Auditory, Brainstem
          Action Potentials
          Funding Source
          Evaluation Research
          Female
          Male
          Adult
          Middle Age
          Aged
          Aged, 80 and Over
          Education, Continuing (Credit)
          Equipment Design
          Electrodes
          Waveforms Evaluation
          Paired T-Tests
          Correlation Coefficient
          Descriptive Statistics
          One-Way Analysis of Variance
          Repeated Measures
          Evoked Potentials, Auditory
          Human
          Adult: 19-44 years
          Middle Aged: 45-64 years
          Aged: 65+ years
          Aged, 80 & over
          Female
          Male
      ab: In this study, differences between electrically evoked whole-nerve action potential (EAP) and electrically evoked auditory brainstem response (EABR) measurements within Nucleus CI24R cochlear implant recipients were evaluated. Precurved modiolus-hugging internal electrode arrays, such as the CI24R, are designed to provide more direct stimulation of neural elements of the modiolus. If the electrode array is closer to the modiolus, electrically evoked and behavioral levels might be lower than were previously recorded for the straight electrode array, the CI24M. EAP and EABR growth functions and behavioral levels were obtained for 10 postlingually deafened adults. Results revealed no significant differences between EAP and EABR threshold levels, and these levels were not significantly lower than those obtained using the CI24M.
      pubtype: Academic Journal
      doctype:
        CEU
        exam questions
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N