Continuous blood gas monitoring using an in-dwelling optode method: comparison to intermittent arterial blood gas sampling in ECMO patients.
INTRODUCTION: The ability to measure postmembrane arterial blood gases is essential in the management of critically ill neonates treated with extracorporeal membrane oxygenation (ECMO). A new technology using, the Paratrend 7 system (Diametrics Medical, High Wycombe,UK) allows for continuous measure...
| Publicado en: | Journal of Perinatology Vol. 22; no. 6; pp. 472 - 475 |
|---|---|
| Autores principales: | , , , |
| Formato: | clinical trial research tables/charts Journal Article |
| Publicado: |
Springer Nature
Sep2002
|
| Acceso en línea: | Ver este registro en EBSCOhost |
| fields | @attributes: recordID: 1 pdfLink: plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106806918&site=ehost-live header: @attributes: shortDbName: ccm uiTerm: 106806918 longDbName: CINAHL Complete uiTag: AN controlInfo: bkinfo: dissinfo: jinfo: jid: 07438346 DZF jtl: Journal of Perinatology issn: 07438346 maglogo: Y pubinfo: dt: Sep2002 vid: 22 iid: 6 pid: 2579 pub: Springer Nature place: Dordrecht, <Blank> artinfo: ui: 106806918 106806918 2003034167 10.1038/sj.jp.7210776 NLM12168125 106806918 ppf: 472 ppct: 3 formats: fmt: @attributes: type: P tig: atl: Continuous blood gas monitoring using an in-dwelling optode method: comparison to intermittent arterial blood gas sampling in ECMO patients. aug: au: Rais-Bahrami K Rivera O Mikesell GT Short BL affil: Department of Neonatology, Children's National Medical Center, 111 Michigan Avenue, NW, Washington, DC 20010 sug: subj: Blood Gas Analysis Methods Extracorporeal Membrane Oxygenation Methods Biophysical Instruments Oxygen Blood Respiratory Distress Syndrome, Newborn Respiratory Distress Syndrome, Newborn Therapy Monitoring, Physiologic Methods Intensive Care Units, Neonatal Critical Care Methods Blood Gas Analysis Equipment and Supplies Catheters Critical Illness Pulmonary Gas Exchange Intervention Trials Infant, Newborn Female Male Human Infant, Newborn: birth-1 month Female Male ab: INTRODUCTION: The ability to measure postmembrane arterial blood gases is essential in the management of critically ill neonates treated with extracorporeal membrane oxygenation (ECMO). A new technology using, the Paratrend 7 system (Diametrics Medical, High Wycombe,UK) allows for continuous measurement of pH, PCO(2) and PO(2), and calculates oxygen saturation, bicarbonate, and base excess. OBJECTIVE: To evaluate and compare the results of continuous blood gas measurement using the Paratrend 7 system with a standard system of blood gas analysis in our intensive care unit. DESIGN: Prospective, controlled, interventional study. SETTING: The neonatal intensive care unit of a tertiary referral center. PATIENTS: Neonates who required extracorporeal life support and were expected to have frequent postmembrane arterial blood sampling during the testing period. RESEARCH DESIGN AND METHOD: To enable Paratrend 7 sensor access to the ECMO circuit, the postmembrane access port extension set that is routinely used for blood drawn for blood gas analysis was used. The study began with the insertion of the Paratrend 7 sensor. Subjects remained on the study until the ECMO was discontinued and/or frequent blood gases were no longer needed. The blood gas results from the Paratrend 7 system were not used in clinical management of the patient. BLOOD GAS MEASUREMENT: During the study period, with each blood sample drawn for laboratory analysis, a printout from the Paratrend 7 monitor was recorded for comparison. RESULTS: A total of 242 pairs of blood gas samples were collected from 10 neonates. The mean bias/precision for pH was -0.02/0.04; for PO(2) 68.35/93.44 mm Hg; and for PCO(2) 1.75/4.23 mm Hg. The correlation (r value) between the sensor reading and the blood gases were 0.89 for pH, 0.96 for PO(2), and 0.73 for PCO(2) (Table 1). CONCLUSION: The blood gases compared in the two methods had a strong correlation for pH, PCO(2) and PO(2).Results of this study indicate that this technology provides an accurate means of monitoring continuous blood gas parameters in neonatal ECMO patients. Use of the Paratrend 7 should allow reduced health-care provider exposure to blood and decreased patient iatrogenic blood loss. pubtype: Academic Journal doctype: clinical trial research tables/charts Journal Article ougenre: Article language: English refInfo: holdings: @attributes: islocal: N |
|---|