Effect of drawing a discard tube on PT and APTT results in healthy adults.

OBJECTIVE: The purpose of this study was to compare results obtained for the prothrombin time (PT) and the activated partial thromboplastin time (APTT) using specimens drawn with and without a discard tube in healthy adults.DESIGN: A specimen of blood in a 3.2% sodium citrate, 5.0 mL tube was drawn...

Descripción completa

Detalles Bibliográficos
Publicado en:Clinical Laboratory Science Vol. 16; no. 1; pp. 16 - 20
Autores principales: Bamberg R, Cottle JN, Williams JC
Formato: research tables/charts Journal Article
Publicado: American Society for Clinical Laboratory Science 2003 Winter
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106847469&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106847469
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        0894959X
        IKL
      jtl: Clinical Laboratory Science
      issn: 0894959X
      maglogo: N
    pubinfo:
      dt: 2003 Winter
      vid: 16
      iid: 1
      pid: 13703
      pub: American Society for Clinical Laboratory Science
      place: Dundee, Michigan
    artinfo:
      ui:
        106847469
        106847469
        2003092456
        NLM12587654
        106847469
      ppf: 16
      ppct: 4
      formats:
      tig:
        atl: Effect of drawing a discard tube on PT and APTT results in healthy adults.
      aug:
        au:
          Bamberg R
          Cottle JN
          Williams JC
        affil: Professor and Chair, Department of Clinical Laboratory Science, School of Allied Health Sciences, East Carolina University, Greenville, NC 27858-4353; bambergw@mail.ecu.edu
      sug:
        subj:
          Blood Specimen Collection Methods
          Partial Thromboplastin Time
          Sodium Citrate
          Comparative Studies
          Paired T-Tests
          Data Analysis Software
          Descriptive Statistics
          Human
      ab: OBJECTIVE: The purpose of this study was to compare results obtained for the prothrombin time (PT) and the activated partial thromboplastin time (APTT) using specimens drawn with and without a discard tube in healthy adults.DESIGN: A specimen of blood in a 3.2% sodium citrate, 5.0 mL tube was drawn from one arm with a discard tube and from the other arm without a discard tube on 35 healthy adults. A PT and APTT were performed on each specimen using a fibrometer.SETTING: The PT and APTT tests were all performed in the student laboratory of the Clinical Laboratory Science Program at East Carolina University.PATIENTS OR OTHER PARTICIPANTS: Study subjects included technician, technologist, and phlebotomist employees of the clinical laboratory at Pitt County Memorial Hospital, and faculty and junior and senior students in the Clinical Laboratory Science Program at East Carolina University, Greenville, North Carolina. All participants signed an informed consent prior to venipuncture.INTERVENTIONS: Two coagulation specimens were drawn from each subject. Specimens in a discard (no anticoagulant) tube and then an anticoagulated tube were drawn from one arm, and a specimen in a single anticoagulant tube was drawn from the other arm. The PT and APTT were performed using standardized procedures with Pacific Hemostasis reagents and controls and a BBL FibroSystem fibrometer.MAIN OUTCOME MEASURES: The degree of difference between PT results and between APTT results for specimens drawn with and without a discard tube.RESULTS: Based on paired t-test analyses, no difference in mean PT results and no difference in mean APTT results were found between specimens drawn with a discard tube and those drawn without a discard tube at an alpha of 0.05. Paired-samples correlation coefficients were significant for both the PT and the APTT at an alpha of 0.05, showing precision between results with and without a discard tube for both coagulation tests.CONCLUSIONS: Relative to sampling from a population of healthy adults, drawing a discard tube before a sodium citrate tube for coagulation testing appears to make an insignificant difference. Replication of these results with patients receiving anticoagulant therapy and/or patients with abnormal coagulation results, would offer cost savings by justifying elimination of discard tubes for blood draws for coagulation testing only. Such a change in protocol would also reduce the likelihood of nosocomial blood loss in vulnerable patient populations.