Analysis of factors affecting quantification of fetomaternal hemorrhage by flow cytometry.

Background: An analysis was carried out to determine the sources and extent of errors encountered in the quantitation of the volume of fetomaternal hemorrhage (FMH) by flow cytometry. Different assay conditions were compared, to define the simplest, most accurate protocol.Study Design and Methods: D...

Descripción completa

Detalles Bibliográficos
Publicado en:Transfusion Vol. 40; no. 11; pp. 1376 - 1377
Autores principales: Kumpel BM, Kumpel, B M
Formato: CEU research tables/charts Journal Article
Publicado: Wiley-Blackwell Nov2000
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=107005535&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 107005535
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        00411132
        1YB
      jtl: Transfusion
      issn: 00411132
      maglogo: Y
    pubinfo:
      dt: Nov2000
      vid: 40
      iid: 11
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        107005535
        107005535
        NLM11099668
        2001023386
        NLM11099668
        107005535
      ppf: 1376
      ppct: 1
      formats:
      tig:
        atl: Analysis of factors affecting quantification of fetomaternal hemorrhage by flow cytometry.
      aug:
        au:
          Kumpel BM
          Kumpel, B M
        affil: International Blood Group Reference Laboratory, Southmead Road, Bristol, United Kingdom
      sug:
        subj:
          Flow Cytometry
          Maternal-Fetal Exchange Evaluation
          Quality Control (Technology)
          Technology, Medical
          Education, Continuing (Credit)
          Funding Source
          Human
      ab: Background: An analysis was carried out to determine the sources and extent of errors encountered in the quantitation of the volume of fetomaternal hemorrhage (FMH) by flow cytometry. Different assay conditions were compared, to define the simplest, most accurate protocol.Study Design and Methods: D-, D+, and artificial FMH (mixtures of D+ and D- RBCs) were stained either by a direct method (using FITC-conjugated IgG3 D MoAb [BRAD-3]), with or without dual labeling with PE-conjugated anti-GPA, or by indirect methods (using polyclonal anti-D followed by FITC- or biotin-conjugated anti-IgG reagents). Cells were selected for flow cytometric analysis on the basis of either forward or side scatter (log FSC/log SSC) characteristics or of GPA+ labeling or were unselected. The numbers of events labeled with anti-D were determined from histograms. For some samples, 10 replicates of 500,000 events each were analyzed.Results: Background fluorescent events in 10 directly labeled gated D- samples ranged from 0.007 to 0.023 percent, equivalent to 0.15- to 0.51-mL FMH. Both the use of a gate on log FSC/SSC or the selection of GPA+ events only resulted in a reduction in FMH of 0.3 mL or less. The intra-assay variation in FMH, or sampling error, was found to be approximately 10 percent at low artificial FMH (<10 mL) but greater (< or =50% with a CV of 15%) with D- samples. Direct staining was quicker and produced a lower background than indirect staining.Conclusion: The inherent sampling error that is due to the random distribution of rare events throughout the blood sample contributed greatly to the variation in the volume of FMH calculated by flow cytometry. The FMH should not be underestimated. For a routine assay, a simplified protocol and calculation will be sufficiently accurate to determine the dose of prophylactic anti-D that should be given to the patient.
      pubtype: Academic Journal
      doctype:
        CEU
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N