Breathing pattern and perception at different levels of volume assist and pressure support in volunteers.

Objective: Volume assist (VA) amplifies the breathing effort whereas pressure support ventilation (PSV) provides a fixed, effort-independent ventilatory support. According to the concept of VA, its level should compensate for the pathologically increased (additional) elastance (Eadd). However, it is...

Full description

Bibliographic Details
Published in:Critical Care Medicine Vol. 29; no. 5; pp. 982 - 989
Main Authors: Mols G, Vetter T, Haberthür C, Geiger K, Guttmann J, Mols, G, Vetter, T, Haberthür, C, Geiger, K, Guttmann, J
Format: research tables/charts Journal Article
Published: Lippincott Williams & Wilkins 2001 May
Online Access:View this record in EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=107042470&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 107042470
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        00903493
        04O
      jtl: Critical Care Medicine
      issn: 00903493
      maglogo: N
    pubinfo:
      dt: 2001 May
      vid: 29
      iid: 5
      pid: 433
      pub: Lippincott Williams & Wilkins
      place: Baltimore, Maryland
    artinfo:
      ui:
        107042470
        107042470
        NLM11378608
        2001071321
        NLM11378608
        107042470
      ppf: 982
      ppct: 7
      formats:
      tig:
        atl: Breathing pattern and perception at different levels of volume assist and pressure support in volunteers.
      aug:
        au:
          Mols G
          Vetter T
          Haberthür C
          Geiger K
          Guttmann J
          Mols, G
          Vetter, T
          Haberthür, C
          Geiger, K
          Guttmann, J
        affil: Department of Anesthesiology and Critical Care Medicine, University of Freiburg, Freiburg, Germany
      sug:
        subj:
          Positive Pressure Ventilation
          Respiration, Artificial Methods
          Respiration
          Respiratory Distress Syndrome, Acute Therapy
          Lung Compliance
          Prospective Studies
          Regression
          Wilcoxon Signed Rank Test
          Analysis of Variance
          Repeated Measures
          Two-Way Analysis of Variance
          Adult
          Female
          Male
          Funding Source
          Human
          Adult: 19-44 years
          Female
          Male
      ab: Objective: Volume assist (VA) amplifies the breathing effort whereas pressure support ventilation (PSV) provides a fixed, effort-independent ventilatory support. According to the concept of VA, its level should compensate for the pathologically increased (additional) elastance (Eadd). However, it is unclear whether breathing subjects prefer an exact compensation of Eadd and whether they are able to adjust the support level by themselves.Design: Prospective, interventional study.Setting: Laboratory.Subjects: Twelve healthy volunteers, nine females, three males, aged 21-33 yrs.Interventions: Increased Eadd was generated by banding of the thorax and abdomen. Volunteers breathed via a mouthpiece with VA or PSV using a positive end-expiratory pressure of 5 cm H2O (0.5 kPa). The study was subdivided into two parts. In part I, volunteers were instructed to adjust the level of VA and PSV themselves starting from three different, randomly applied levels in each mode (2, 8, 14 cm H2O or cm H2O/L; 0.2, 0.8, 1.4 kPa[/L]). In part II, 20 levels of VA and PSV (1-20 cm H2O or cm H2O/L, 0.1-2 kPa[/L]) were randomly selected by an investigator and estimated by the volunteers using a visual analog scale. Additionally, the breathing pattern was characterized.Measurements and Main Results: Eadd (7.1 +/- 1.5 cm H2O/L [0.7 +/- 0.2 kPa/L], mean +/- sd) corresponded almost exactly to the "self-adjusted" VA level of part I (7.0 +/- 3.3 cm H2O/L [0.7 +/- 0.3 kPa/L]) and to the adequate level of part II (8-9 cm H2O/L [0.8-0.9 kPa/L]). The accordant PSV levels were 5.7 +/- 2.6 cm H2O (0.6 +/- 0.3 kPa) and 6-7 cm H2O (0.6-0.7 kPa). The breathing pattern was less influenced by changes of the support level with VA compared with PSV, which may explain in part the greater comfort of VA.Conclusions: We confirmed the theoretical assumption that VA should be adapted to Eadd. Furthermore, we demonstrated that conscious subjects are able to adjust the level of VA and PSV themselves.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N