Photostimulable storage phosphor image acquisition: evaluation of three commercially available state-of-the-art systems...Proccedings of the 16th Symposium for Computer Applications in Radiology. 'PACS: Performance Improvement in Radiology.' Houston TX, May 6-9, 1999

Photostimulable storage phosphor (PSP) image acquisition systems have been available for several years. The technology has had the opportunity to mature; however, there has not been an independent comparison of recently marketed commercial systems. For this study, three computed radiography (CR) sys...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Digital Imaging Vol. 12; pp. 54 - 59
Autores principales: Tucker JE, Contreras M, Wider RJ, Radvany MG, Chacko AK, Shah RB
Formato: research tables/charts Journal Article
Publicado: Springer Nature May1999 Supplement
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=107211421&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 107211421
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        08971889
        DOQ
      jtl: Journal of Digital Imaging
      issn: 08971889
      maglogo: N
    pubinfo:
      dt: May1999 Supplement
      vid: 12
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        107211421
        107211421
        1999061195
        NLM10342166
        107211421
      ppf: 54
      ppct: 5
      formats:
      tig:
        atl: Photostimulable storage phosphor image acquisition: evaluation of three commercially available state-of-the-art systems...Proccedings of the 16th Symposium for Computer Applications in Radiology. 'PACS: Performance Improvement in Radiology.' Houston TX, May 6-9, 1999
      aug:
        au:
          Tucker JE
          Contreras M
          Wider RJ
          Radvany MG
          Chacko AK
          Shah RB
        affil: Department of Radiology, Brooke Army Medical Center, Fort Sam Houston, TX 78234-6200
      sug:
        subj:
          Radiography, Computed
          Image Processing, Computer Assisted
          Radiographic Image Enhancement
          Technology, Radiologic
          Comparative Studies
          Evaluation Research
          Human
      ab: Photostimulable storage phosphor (PSP) image acquisition systems have been available for several years. The technology has had the opportunity to mature; however, there has not been an independent comparison of recently marketed commercial systems. For this study, three computed radiography (CR) systems using PSP technology (Kodak CR System 400 with autoloader [Eastman Kodak, Rochester, NY], Fuji FCR AC-3CS [Fuji Medical Systems, Stamford, CT], and Agfa ADC Compact [Bayer Corp, Ridgefield Park, NJ]) were connected to an IBM RadWorks diagnostic radiology workstation (IBM Corp, White Plains, NY) and evaluated for conformance to their performance specifications using guidance provided in the most recent draft acceptance testing protocol from Task Group No. 10, American Association of Physicists in Medicine. In addition, the physical requirements (e.g., space and power) and connectivity to another manufacturer's diagnostic workstation were examined. X-ray technologist comfort with each PSP imaging system and an assessment by our supporting biomedical equipment maintenance activity of their ability to service each PSP imaging system were also considered. Copyright (c) 1999 by W.B. Saunders Company
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N