Intrasubject Variability in Power Reflectance.

Background: Power reflectance measurements are an active area of research related to the development of noninvasive middle-ear assessment methods. There are limited data related to test-retest measures of power reflectance. Purpose: This study investigates test-retest features of power reflectance,...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of the American Academy of Audiology Vol. 25; no. 5; pp. 441 - 449
Autores principales: Abur, Defne, Horton, Nicholas J., Voss, Susan E.
Formato: research tables/charts Journal Article
Publicado: Thieme Medical Publishing Inc. May2014
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=107830750&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 107830750
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        10500545
        9OC
      jtl: Journal of the American Academy of Audiology
      issn: 10500545
      maglogo: Y
    pubinfo:
      dt: May2014
      vid: 25
      iid: 5
      pid: 2811
      pub: Thieme Medical Publishing Inc.
      place: New York, New York
    artinfo:
      ui:
        107830750
        98631258
        10.3766/jaaa.25.5.3
        NLM25257718
        107830750
      ppf: 441
      ppct: 8
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Intrasubject Variability in Power Reflectance.
      aug:
        au:
          Abur, Defne
          Horton, Nicholas J.
          Voss, Susan E.
        affil: Picker Engineering Program, Ford Hall, Smith College, Northampton, MA
      sug:
        subj:
          Ear, Middle Physiology
          Speech Acoustics
          Acoustic Impedance Tests
          Human
          Repeated Measures
          Female
          Adult
          Students, Undergraduate
          Descriptive Statistics
          Data Analysis Software
          P-Value
          Adult: 19-44 years
          Female
      ab: Background: Power reflectance measurements are an active area of research related to the development of noninvasive middle-ear assessment methods. There are limited data related to test-retest measures of power reflectance. Purpose: This study investigates test-retest features of power reflectance, including comparisons of intrasubject versus intersubject variability and how ear-canal measurement location affects measurements. Research Design: Repeated measurements of power reflectance were made at about weekly intervals. The subjects returned for four to eight sessions. Measurements were made at three ear-canal locations: a deep insertion depth (with a foam plug flush at the entrance to the ear canal) and both 3 and 6 mm more lateral to this deep insertion. Study Sample: Repeated measurements on seven subjects are reported. All subjects were female, between 19 and 22 yr old, and enrolled at an undergraduate women’s college. Data Collection and Analysis: Measurements on both the right and left ears were made at three ear-canal locations during each of four to eight measurement sessions. Random-effects regression models were used for the analysis to account for repeated measures within subjects. The mean power reflectance for each position over all sessions was calculated for each subject. Results: The comparison of power reflectance from the left and right ears of an individual subject varied greatly over the seven subjects; the difference between the power reflectance measured on the left and that measured on the right was compared at 248 frequencies, and depending on the subject, the percentage of tested frequencies for which the left and right ears differed significantly ranged from 10% to 93% (some with left values greater than right values and others with the opposite pattern). Although the individual subjects showed left-right differences, the overall population generally did not show significant differences between the left and right ears. The mean power reflectance for each measurement position over all sessions depended on the location of the probe in the ear for frequencies of less than 1000 Hz. The standard deviation between subjects’ mean power reflectance after controlling for ear (left or right) was found to be greater than the standard deviation within the individual subject’s mean power reflectance. The intrasubject standard deviation in power reflectance was smallest at the deepest insertion depths. Conclusions: All subjects had differences in power reflectance between their left and right ears at some frequencies; the percentage of frequencies at which differences occurred varied greatly across subjects. The intrasubject standard deviations were smallest for the deepest probe insertion depths, suggesting clinical measurements should be made with as deep an insertion as practically possible to minimize variability. This deep insertion will reduce both acoustic leaks and the effect of low-frequency ear-canal losses. The within-subject standard deviations were about half the magnitude of the overall standard deviations, quantifying the extent of intrasubject versus intersubject variability.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N