Comparative Efficacy of New Interfaces for Intra-procedural Imaging Review: the Microsoft Kinect, Hillcrest Labs Loop Pointer, and the Apple iPad.

We adapted and evaluated the Microsoft Kinect (touchless interface), Hillcrest Labs Loop Pointer (gyroscopic mouse), and the Apple iPad (multi-touch tablet) for intra-procedural imaging review efficacy in a simulation using MIM Software DICOM viewers. Using each device, 29 radiologists executed five...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Digital Imaging Vol. 27; no. 4; pp. 463 - 470
Autores principales: Chao, Cherng, Tan, Justin, Castillo, Edward, Zawaideh, Mazen, Roberts, Anne, Kinney, Thomas
Formato: pictorial research tables/charts Journal Article
Publicado: Springer Nature 2014 Aug
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=107862552&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 107862552
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        08971889
        DOQ
      jtl: Journal of Digital Imaging
      issn: 08971889
      maglogo: N
    pubinfo:
      dt: 2014 Aug
      vid: 27
      iid: 4
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        107862552
        107862552
        2012639445
        10.1007/s10278-014-9687-y
        NLM24706159
        107862552
      ppf: 463
      ppct: 7
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Comparative Efficacy of New Interfaces for Intra-procedural Imaging Review: the Microsoft Kinect, Hillcrest Labs Loop Pointer, and the Apple iPad.
      aug:
        au:
          Chao, Cherng
          Tan, Justin
          Castillo, Edward
          Zawaideh, Mazen
          Roberts, Anne
          Kinney, Thomas
        affil: UCSD Medical Center, 200 West Arbor Drive San Diego 92103-8756 USA
      sug:
        subj:
          Digital Imaging
          Equipment Design
          User-Computer Interface
          Computers, Hand-Held
          Video Games
          Surveys
          Tomography, X-Ray Computed
          Analysis of Variance
          Repeated Measures
          Picture Archiving and Communication Systems
          P-Value
          T-Tests
          Data Analysis Software
          Adult
          Middle Age
          Asepsis
          Adult: 19-44 years
          Middle Aged: 45-64 years
      ab: We adapted and evaluated the Microsoft Kinect (touchless interface), Hillcrest Labs Loop Pointer (gyroscopic mouse), and the Apple iPad (multi-touch tablet) for intra-procedural imaging review efficacy in a simulation using MIM Software DICOM viewers. Using each device, 29 radiologists executed five basic interactions to complete the overall task of measuring an 8.1-cm hepatic lesion: scroll, window, zoom, pan, and measure. For each interaction, participants assessed the devices on a 3-point subjective scale (3 = highest usability score). The five individual scores were summed to calculate a subjective composite usability score (max 15 points). Overall task time to completion was recorded. Each user also assessed each device for its potential to jeopardize a sterile field. The composite usability scores were as follows: Kinect 9.9 (out of 15.0; SD = 2.8), Loop Pointer 12.9 (SD = 13.5), and iPad 13.5 (SD = 1.8). Mean task completion times were as follows: Kinect 156.7 s (SD = 86.5), Loop Pointer 51.5 s (SD = 30.6), and iPad 41.1 s (SD = 25.3). The mean hepatic lesion measurements were as follows: Kinect was 7.3 cm (SD = 0.9), Loop Pointer 7.8 cm (SD = 1.1), and iPad 8.2 cm (SD = 1.2). The mean deviations from true hepatic lesion measurement were as follows: Kinect 1.0 cm and for both the Loop Pointer and iPad, 0.9 cm (SD = 0.7). The Kinect had the least and iPad had the most subjective concern for compromising the sterile field. A new intra-operative imaging review interface may be near. Most surveyed foresee these devices as useful in procedures, and most do not anticipate problems with a sterile field. An ideal device would combine iPad's usability and accuracy with the Kinect's touchless aspect.
      pubtype: Academic Journal
      doctype:
        pictorial
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N