Accuracy of Clinical Protocols in SPECT.

The accuracy of clinical SPECT is highly dependent on the acquisition and processing parameters, which are selected according to the clinical task. These parameters are usually set within protocols in order to allow for standardization from one study to another and to speed up the clinical routine....

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Nuclear Medicine Technology Vol. 40; no. 4; pp. 259 - 265
Autores principales: Kurt A, Bor D, Tastan S, Donmez S, Haciosmanoglu T
Formato: research Journal Article
Publicado: Society of Nuclear Medicine Dec2012
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=108082827&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 108082827
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        00914916
        H7Q
      jtl: Journal of Nuclear Medicine Technology
      issn: 00914916
      maglogo: N
    pubinfo:
      dt: Dec2012
      vid: 40
      iid: 4
      pid: 2576
      pub: Society of Nuclear Medicine
      place: Reston, Virginia
    artinfo:
      ui:
        108082827
        2011789268
        10.2967/jnmt.111.098715
        NLM23024337
        108082827
      ppf: 259
      ppct: 6
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Accuracy of Clinical Protocols in SPECT.
      aug:
        au:
          Kurt A
          Bor D
          Tastan S
          Donmez S
          Haciosmanoglu T
        affil: 1Department of Medical Physics, Institute of Nuclear Sciences, Ankara University, Ankara, Turkey.
      sug:
        subj:
          Tomography, Emission-Computed, Single-Photon Methods
          Human
          Image Processing, Computer Assisted
          Phantoms, Imaging
          Sensitivity and Specificity
          Software
      ab: The accuracy of clinical SPECT is highly dependent on the acquisition and processing parameters, which are selected according to the clinical task. These parameters are usually set within protocols in order to allow for standardization from one study to another and to speed up the clinical routine. METHODS: In the first part of this work, tomographic images of a Jaszczak phantom were obtained on 5 different SPECT systems using 2 common clinical protocols and each system's default acquisition and processing parameters. In the second part, tomographic images of the Jaszczak phantom were obtained using identical acquisition and processing parameters on all systems. Projection data were then transferred to other system software for reconstruction. RESULTS: For the first part of the work, variation in image quality was seen quantitatively among the systems, even when clinical protocols with the same aim were used. The accuracy of the similar reconstruction algorithms and data transfer was determined and summarized. In the second part of this study, the performance of the SPECT systems using similar acquisition protocols and reconstruction software was determined and summarized. CONCLUSION: The default clinical protocols offered by the manufacturer for similar studies may be different from one another. The user should modify these protocols using phantom studies and standardize same-purpose protocols among different software programs.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N