3.0T, time-resolved, 3D flow-sensitive MR in the thoracic aorta: Impact of k-t BLAST acceleration using 8- versus 32-channel coil arrays.

Purpose: To evaluate the performance of 4D flow MR in the thoracic aorta with 8- and 32-channel coil arrays using k-t BLAST and SENSE acceleration techniques and compare this to a conventional 2D SENSE approach. Materials and Methods: Fifteen healthy subjects and eight patients underwent magnetic re...

Full description

Bibliographic Details
Published in:Journal of Magnetic Resonance Imaging Vol. 42; no. 2; pp. 495 - 505
Main Authors: Zaman, Arshad, Motwani, Manish, Oliver, James J., Crelier, Gerard, Dobson, Laura E., Higgins, David M., Plein, Sven, Greenwood, John P.
Format: research Journal Article
Published: Wiley-Blackwell Aug2015
Online Access:View this record in EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=108427196&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 108427196
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        10531807
        O63
      jtl: Journal of Magnetic Resonance Imaging
      issn: 10531807
      maglogo: Y
    pubinfo:
      dt: Aug2015
      vid: 42
      iid: 2
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        108427196
        108427196
        NLMO63080115-00003
        108427196
        10.1002/jmri.24814
        NLM25447784
        108427196
      ppf: 495
      ppct: 10
      formats:
      tig:
        atl: 3.0T, time-resolved, 3D flow-sensitive MR in the thoracic aorta: Impact of k-t BLAST acceleration using 8- versus 32-channel coil arrays.
      aug:
        au:
          Zaman, Arshad
          Motwani, Manish
          Oliver, James J.
          Crelier, Gerard
          Dobson, Laura E.
          Higgins, David M.
          Plein, Sven
          Greenwood, John P.
        affil: Multidisciplinary Cardiovascular Research Centre, Division of Cardiovascular and Diabetes Research, Leeds Institute of Genetics, Health & Therapeutics, University of Leeds, Leeds UK
      sug:
        subj:
          Transducers
          Magnetic Resonance Angiography Equipment and Supplies
          Image Enhancement Equipment and Supplies
          Imaging, Three-Dimensional Methods
          Aorta, Thoracic Physiology
          Blood Flow Velocity Physiology
          Signal Processing, Computer Assisted Equipment and Supplies
          Middle Age
          Equipment Design
          Equipment Failure
          Female
          Male
          Human
          Sensitivity and Specificity
          Adult
          Young Adult
          Reference Values
          Reproducibility of Results
          Validation Studies
          Comparative Studies
          Evaluation Research
          Multicenter Studies
          Middle Aged: 45-64 years
          Adult: 19-44 years
          Female
          Male
      ab: Purpose: To evaluate the performance of 4D flow MR in the thoracic aorta with 8- and 32-channel coil arrays using k-t BLAST and SENSE acceleration techniques and compare this to a conventional 2D SENSE approach. Materials and Methods: Fifteen healthy subjects and eight patients underwent magnetic resonance imaging (MRI) at 3.0T using: 1) 2D SENSE phase contrast velocity mapping as the reference standard and 2) 4D-flow pulse sequences accelerated with SENSE and k-t BLAST, using both 8- and 32-channel coil arrays. Data processing was performed using GT Flow. Image quality of the magnitude images and pathline visualization were graded and mean scan times, flow, peak velocity, stroke volume, and image quality were compared between techniques. Results: Mean scan times were significantly lower for 4D-flow sequences accelerated with k-t BLAST compared to SENSE (5.5 vs. 25.2 min; P < 0.01). 4D k-t BLAST acquisition had greater magnitude and pathline image quality than 4D SENSE acquisition for both 32-channel and 8-channel data (P < 0.001); both 4D SENSE and 4D k-t BLAST acquisitions had significantly greater image quality when 32 channels were utilized compared to 8 (P < 0.05). On Bland-Altman analysis, all 4D flow pulse sequences showed significant agreement with the 2D SENSE reference for peak velocity measurement (P > 0.05); the lowest bias being observed with the 4D 32 channel k-t BLAST sequence. There were no significant differences in measured flow, peak velocity, or stroke volume with any of the four investigated 4D acquisition techniques compared to reference technique values (P > 0.05). In patients, there were no significant differences in flow, peak velocity, or stroke volume measurements between 32-channel 4D k-t BLAST and the reference acquisition. Conclusion: 4D flow MR using k-t BLAST and 32 channel coils allows a reduction in total scan time while improving overall image quality compared to a standard 2D SENSE and 4D SENSE acquisitions. The use of 32 channels rather than 8 channels with the 4D k-t BLAST was also preferable in terms of image quality.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N