Gunnar Optiks Study #2: Electromyography and Tear Volume.

Background: This study was conducted to study the difference between the classic Gunnar Optiks computer spectacles and control glasses with small changes in base curve or tint. Methods: Twenty-nine subjects, ages 22-62, completed this study. The two control pairs of eyeglasses were in similar frames...

Descripción completa

Detalles Bibliográficos
Publicado en:Optometry & Visual Performance Vol. 3; no. 5; pp. 218 - 223
Autores principales: Kundart, James, Hayes, John, Yu-Chi Tai, Sheedy, James E.
Formato: research tables/charts Journal Article
Publicado: Optometric Extension Program Aug2015
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=109006488&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 109006488
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        23253479
        HOOW
      jtl: Optometry & Visual Performance
      issn: 23253479
      maglogo: N
    pubinfo:
      dt: Aug2015
      vid: 3
      iid: 5
      pid: 46881
      pub: Optometric Extension Program
      place: Lutherville Timonium, Maryland
    artinfo:
      ui:
        109006488
        109006488
        109006488
        109006488
      ppf: 218
      ppct: 5
      formats:
      tig:
        atl: Gunnar Optiks Study #2: Electromyography and Tear Volume.
      aug:
        au:
          Kundart, James
          Hayes, John
          Yu-Chi Tai
          Sheedy, James E.
        affil: Pacific University College of Optometry, Forest Grove, Oregon
      sug:
        subj:
          Variance Analysis
          Eyeglasses
          Blinking
          Analysis of Variance
          Confidence Intervals
          Questionnaires
          Sensitivity and Specificity
          Surveys
      ab: Background: This study was conducted to study the difference between the classic Gunnar Optiks computer spectacles and control glasses with small changes in base curve or tint. Methods: Twenty-nine subjects, ages 22-62, completed this study. The two control pairs of eyeglasses were in similar frames, and both sets of lenses were made of similar resin with antireflective coating. One control pair had gray-tinted (neutral density) lenses made with the same optical power as the Gunnar Optiks design. The other had the same yellow tint but a flatter base curve and less faceform than the Gunnar design. Under stressful conditions of glare and dry air induced by a fan, electromyography of the eyelid to quantify squinting and blinking experienced with each type of glasses and tear volume measurement using Zone Quick phenol red thread were recorded. Conditions were compared with a mixed-model analysis of variance or covariance. Results: Statistical analysis revealed no significant difference between the Gunnar Optiks design and the control glasses under these conditions. There were no significant differences in squint power (F=1.88, p=0.083) and squint frequency (F=2.065, p=0.057) between the Gunnar Optiks design and the control eyeglasses with a neutral density tint or flatter base curve. There was significantly increased tear volume (F=3.65, p=0.031) and reduced blinking (F=2.57, p=0.019), but a lower blink rate is associated with dry eye. Conclusion: The classic Gunnar Optiks design was not shown tofulfill their claims of reducing asthenopia due to normalization of blink rate or squinting.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N