Virtual iron concentration imaging based on dual-energy CT for noninvasive quantification and grading of liver iron content: An iron overload rabbit model study.

Objectives: To assess the accuracy of liver iron content (LIC) quantification and grading ability associated with clinical LIC stratification using virtual iron concentration (VIC) imaging on dual-energy CT (DECT) in an iron overload rabbit model.Methods: Fifty-one rabbits were prepared as iron-load...

Full description

Bibliographic Details
Published in:European Radiology Vol. 25; no. 9; pp. 2657 - 2665
Main Authors: Luo, Xian Fu, Yang, Yi, Yan, Jing, Xie, Xue Qian, Zhang, Huan, Chai, Wei Min, Wang, Li, Schmidt, Bernhard, Yan, Fu Hua
Format: Journal Article
Published: Springer Nature Sep2015
Online Access:View this record in EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=109616226&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 109616226
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: Sep2015
      vid: 25
      iid: 9
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        109616226
        NLM25773943
        2013116105
        10.1007/s00330-015-3693-4
        NLM25773943
        109616226
      ppf: 2657
      ppct: 8
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Virtual iron concentration imaging based on dual-energy CT for noninvasive quantification and grading of liver iron content: An iron overload rabbit model study.
      aug:
        au:
          Luo, Xian Fu
          Yang, Yi
          Yan, Jing
          Xie, Xue Qian
          Zhang, Huan
          Chai, Wei Min
          Wang, Li
          Schmidt, Bernhard
          Yan, Fu Hua
      sug:
      ab: Objectives: To assess the accuracy of liver iron content (LIC) quantification and grading ability associated with clinical LIC stratification using virtual iron concentration (VIC) imaging on dual-energy CT (DECT) in an iron overload rabbit model.Methods: Fifty-one rabbits were prepared as iron-loaded models by intravenous injection of iron dextran. DECT was performed at 80 and 140 kVp. VIC images were derived from an iron-specific algorithm. Postmortem LIC assessments were conducted on an inductively coupled plasma (ICP) spectrometer. Correlation between VIC and LIC was analyzed. VIC were stratified according to the corresponding clinical LIC thresholds of 1.8, 3.2, 7.0, and 15.0 mg Fe/g. Diagnostic performance of stratification was evaluated by receiver operating characteristic analysis.Results: VIC linearly correlated with LIC (r = 0.977, P < 0.01). No significant difference was observed between VIC-derived LICs and ICP (P > 0.05). For the four clinical LIC thresholds, the corresponding cutoff values of VIC were 19.6, 25.3, 36.9, and 61.5 HU, respectively. The highest sensitivity (100%) and specificity (100 %) were achieved at the threshold of 15.0 mg Fe/g.Conclusions: Virtual iron concentration imaging on DECT showed potential ability to accurately quantify and stratify hepatic iron accumulation in the iron overload rabbit model.Key Points: • Virtual iron concentration (VIC) linearly correlates with liver iron content (LIC). • VIC accurately quantifies LIC. • VIC accurately grades LIC based on clinical LIC stratification.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N