Diagnostic accuracy of reused Pronto Drytest and CLOtest in the detection of Helicobacter pylori infection.

Background: Unchanged substrate in a negative rapid urease test may be reused to detect Helicobacter pylori (H. pylori). This could potentially reduce costs and wastage in low prevalence and resource-poor settings. We thus aimed to investigate the diagnostic accuracy of reused Pronto Dry and CLOtest...

Descripción completa

Detalles Bibliográficos
Publicado en:BMC Gastroenterology Vol. 15; no. 1; pp. 101 - 102
Autores principales: Jamaludin, Shahidi, Mustaffa, Nazri, Che Hamzah, Nor Aizal, Syed Abdul Aziz, Syed Hassan, Lee, Yeong Yeh
Formato: Journal Article
Publicado: BioMed Central 2015
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=109620775&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 109620775
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        1471230X
        1CHO
      jtl: BMC Gastroenterology
      issn: 1471230X
      maglogo: N
    pubinfo:
      dt: 2015
      vid: 15
      iid: 1
      pid: 24147
      pub: BioMed Central
    artinfo:
      ui:
        109620775
        NLM26264957
        2013128963
        10.1186/s12876-015-0332-0
        NLM26264957
        PMC4534069
        109620775
      ppf: 101
      ppct: 1
      formats:
      tig:
        atl: Diagnostic accuracy of reused Pronto Drytest and CLOtest in the detection of Helicobacter pylori infection.
      aug:
        au:
          Jamaludin, Shahidi
          Mustaffa, Nazri
          Che Hamzah, Nor Aizal
          Syed Abdul Aziz, Syed Hassan
          Lee, Yeong Yeh
      sug:
      ab: Background: Unchanged substrate in a negative rapid urease test may be reused to detect Helicobacter pylori (H. pylori). This could potentially reduce costs and wastage in low prevalence and resource-poor settings. We thus aimed to investigate the diagnostic accuracy of reused Pronto Dry and CLOtest kits, comparing this to the use of new Pronto Dry test kits and histopathological evaluation of gastric mucosal biopsies.Methods: Using a cross-sectional study design, subjects who presented for upper endoscopy due to various non-emergent causes had gastric biopsies obtained at three adjacent sites. Biopsy samples were tested for H. pylori using a reused Pronto Dry test, a reused CLOtest, a new Pronto Dry test and histopathological examination. Concordance rates, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy were then determined.Results: A total of 410 subjects were recruited. The sensitivity and diagnostic accuracy of reused Pronto Dry tests were 72.60 % (95% CI, 61.44 - 81.51) and 94.15% (95% CI, 91.44 - 96.04) respectively. For reused CLOtests, the sensitivity and diagnostic accuracy were 93.15% (95% CI 85.95 - 97.04) and 98.29% (95% CI 96.52 - 99.17) respectively. There were more true positives for new and reused Pronto Dry pallets as compared to new and reused CLOtests when comparing colour change within 30 min vs. 31-60 min (P < 0.001 and P = 0.7 respectively).Conclusion: Negative Pronto Dry and CLOtest kits may be reused in a low prevalence setting where cost issues remain paramount. Reused CLOtest kits have better accuracy than reused Pronto Dry tests. Reused Pronto Dry tests however have a more rapid colour change whilst maintaining diagnostic accuracy.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N