Clinical applications of the C-arm cone-beam CT-based 3D needle guidance system in performing percutaneous transthoracic needle biopsy of pulmonary lesions.

Purpose: This study explored the value of flat detector C-arm CT-guidance system in performing percutaneous transthoracic needle biopsy (PTNB) for lung lesions in clinical practice.Methods: A total of 110 patients with solid lung lesions were enrolled to undergo PTNB procedures. The mean diameter of...

Descripción completa

Detalles Bibliográficos
Publicado en:Diagnostic & Interventional Radiology Vol. 20; no. 6; pp. 470 - 475
Autores principales: Jiao, De Chao, Li, Teng Fei, Han, Xin Wei, Wu, Gang, Ma, Ji, Fu, Ming Ti, Sun, Qi, Beilner, Janina
Formato: Journal Article
Publicado: Galenos Yayinevi Tic. LTD. STI Nov/Dec2014
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=109682887&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 109682887
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        13053825
        39NM
      jtl: Diagnostic & Interventional Radiology
      issn: 13053825
      maglogo: N
    pubinfo:
      dt: Nov/Dec2014
      vid: 20
      iid: 6
      pid: 28155
      pub: Galenos Yayinevi Tic. LTD. STI
    artinfo:
      ui:
        109682887
        NLM25323838
        2012786015
        10.5152/dir.2014.13463
        NLM25323838
        PMC4463285
        109682887
      ppf: 470
      ppct: 5
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Clinical applications of the C-arm cone-beam CT-based 3D needle guidance system in performing percutaneous transthoracic needle biopsy of pulmonary lesions.
      aug:
        au:
          Jiao, De Chao
          Li, Teng Fei
          Han, Xin Wei
          Wu, Gang
          Ma, Ji
          Fu, Ming Ti
          Sun, Qi
          Beilner, Janina
      sug:
      ab: Purpose: This study explored the value of flat detector C-arm CT-guidance system in performing percutaneous transthoracic needle biopsy (PTNB) for lung lesions in clinical practice.Methods: A total of 110 patients with solid lung lesions were enrolled to undergo PTNB procedures. The mean diameter of lesions was 4.63 cm (range, 0.6-15cm). The needle path was carefully planned and calculated on the C-arm CT system, which acquired three-dimensional CT-like cross-sectional images. The PTNB procedures were performed under needle guidance with fluoroscopic feedbacks.Results: Histopathologic tissue was successfully obtained from 108 patients with a puncture success rate of 98.2% (108/110). The diagnostic accuracy rate was found to be 96.3% (104/108). There was only one case of pneumothorax (0.9%) requiring therapy. The rates of mild pneumothorax and hemoptysis were low (12.0% and 6.5%, respectively). In addition, procedural time could be limited with this technique, which helped to reduce X-ray exposure.Conclusion: Our study shows that C-arm CT-based needle guidance enables reliable and efficient needle positioning and progression by providing real-time intraoperative guidance.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N