A comparison of axial versus coronal image viewing in computer-aided detection of lung nodules on CT.

Purpose: To compare primarily viewing axial images (Axial mode) versus coronal reconstruction images (Coronal mode) in computer-aided detection (CAD) of lung nodules on multidetector computed tomography (CT) in terms of detection performance and reading time.Materials and Methods: Sixty CT data sets...

Descripción completa

Detalles Bibliográficos
Publicado en:Japanese Journal of Radiology Vol. 33; no. 2; pp. 76 - 84
Autores principales: Iwasawa, Tae, Matsumoto, Sumiaki, Aoki, Takatoshi, Okada, Fumito, Nishimura, Yoshihiro, Yamagata, Hitoshi, Ohno, Yoshiharu
Formato: research Journal Article
Publicado: Springer Nature Feb2015
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=109702427&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 109702427
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        18671071
        AUCM
      jtl: Japanese Journal of Radiology
      issn: 18671071
      maglogo: N
    pubinfo:
      dt: Feb2015
      vid: 33
      iid: 2
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        109702427
        NLM25533196
        2012908416
        10.1007/s11604-014-0383-0
        NLM25533196
        109702427
      ppf: 76
      ppct: 8
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: A comparison of axial versus coronal image viewing in computer-aided detection of lung nodules on CT.
      aug:
        au:
          Iwasawa, Tae
          Matsumoto, Sumiaki
          Aoki, Takatoshi
          Okada, Fumito
          Nishimura, Yoshihiro
          Yamagata, Hitoshi
          Ohno, Yoshiharu
      sug:
      ab: Purpose: To compare primarily viewing axial images (Axial mode) versus coronal reconstruction images (Coronal mode) in computer-aided detection (CAD) of lung nodules on multidetector computed tomography (CT) in terms of detection performance and reading time.Materials and Methods: Sixty CT data sets from two institutions were collected prospectively. Ten observers (6 radiologists, 4 pulmonologists) with varying degrees of experience interpreted the data sets using CAD as a second reader (performing nodule detection first without then with aid). The data sets were interpreted twice, once each for Axial and Coronal modes, in two sessions held 4 weeks apart. Jackknife free-response receiver-operating characteristic analysis was used to compare detection performances in the two modes.Results: Mean figure-of-merit values with and without aid were 0.717 and 0.684 in Axial mode and 0.702 and 0.671 in Coronal mode; use of CAD significantly increased the performance of observers in both modes (P < 0.01). Mean reading times for radiologists did not significantly differ between Axial (156 ± 74 s) and Coronal mode (164 ± 69 s; P = 0.08). Mean reading times for pulmonologists were significantly lower in Coronal (112 ± 53 s) than in Axial mode (130 ± 80 s; P < 0.01).Conclusion: There was no statistically significant difference between Axial and Coronal modes for lung nodule detection with CAD.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N