Cross-vendor validation of liver magnetic resonance elastography.

Purpose: To evaluate and validate the reproducibility of MR Elastography (MRE)-derived liver stiffness values on two different MR vendor platforms performed on the same subject on the same day. Methods: This investigation was approved by the hospital IRB. MRE exams were performed twice in identical...

Full description

Bibliographic Details
Published in:Abdominal Imaging Vol. 40; no. 4; pp. 789 - 795
Main Authors: Serai, Suraj D, Yin, Meng, Wang, Hui, Ehman, Richard L, Podberesky, Daniel J
Format: research Journal Article
Published: Springer Nature Apr2015
Online Access:View this record in EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=109714330&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 109714330
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09428925
        O52
      jtl: Abdominal Imaging
      issn: 09428925
      maglogo: N
    pubinfo:
      dt: Apr2015
      vid: 40
      iid: 4
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        109714330
        NLM25476489
        2012950417
        10.1007/s00261-014-0282-y
        NLM25476489
        PMC4523216
        109714330
      ppf: 789
      ppct: 6
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Cross-vendor validation of liver magnetic resonance elastography.
      aug:
        au:
          Serai, Suraj D
          Yin, Meng
          Wang, Hui
          Ehman, Richard L
          Podberesky, Daniel J
      sug:
      ab: Purpose: To evaluate and validate the reproducibility of MR Elastography (MRE)-derived liver stiffness values on two different MR vendor platforms performed on the same subject on the same day. Methods: This investigation was approved by the hospital IRB. MRE exams were performed twice in identical fashion in eight volunteers and in five clinical patients on two different 1.5 T MR scanners-once on a Philips MR scanner and immediately afterward in back-to-back fashion on a General Electric MR scanner, or vice versa. All scan parameters were kept identical on the two platforms to the best extent possible. After the MRE magnitude and phase images were obtained, the data were converted into quantitative images displaying the stiffness of the liver parenchyma. Mean liver stiffness values between the two platforms were compared using interclass correlation with a p value <0.05 considered statistically significant. Results: Interclass correlation coefficient (ICC) value of 0.994 was obtained for 13 subjects with p value <0.001 indicating a significantly positive correlation. Conclusion: As MRE gains in acceptance and as its availability becomes more widespread, it is important to ascertain and confirm that liver stiffness values obtained on different MRE vendor platforms are consistent and reproducible. In this small pilot investigation, we demonstrate that liver stiffness measurement with MRE is reproducible and has very good consistency across two vendor platforms.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N