Median prior constrained TV algorithm for sparse view low-dose CT reconstruction.
It is known that lowering the X-ray tube current (mAs) or tube voltage (kVp) and simultaneously reducing the total number of X-ray views (sparse view) is an effective means to achieve low-dose in computed tomography (CT) scan. However, the associated image quality by the conventional filtered back-p...
| Published in: | Computers in Biology & Medicine Vol. 60; pp. 117 - 132 |
|---|---|
| Main Authors: | , , , , , |
| Format: | Journal Article |
| Published: |
Elsevier B.V.
2015
|
| Online Access: | View this record in EBSCOhost |
| fields | @attributes: recordID: 1 pdfLink: plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=109720989&site=ehost-live header: @attributes: shortDbName: ccm uiTerm: 109720989 longDbName: CINAHL Complete uiTag: AN controlInfo: bkinfo: dissinfo: jinfo: jid: 00104825 JC2 jtl: Computers in Biology & Medicine issn: 00104825 maglogo: N pubinfo: dt: 2015 vid: 60 pid: 82545 pub: Elsevier B.V. place: Philadelphia, Pennsylvania artinfo: ui: 109720989 NLM25817533 2012970093 10.1016/j.compbiomed.2015.03.003 NLM25817533 109720989 ppf: 117 ppct: 15 formats: tig: atl: Median prior constrained TV algorithm for sparse view low-dose CT reconstruction. aug: au: Liu, Yi Shangguan, Hong Zhang, Quan Zhu, Hongqing Shu, Huazhong Gui, Zhiguo sug: ab: It is known that lowering the X-ray tube current (mAs) or tube voltage (kVp) and simultaneously reducing the total number of X-ray views (sparse view) is an effective means to achieve low-dose in computed tomography (CT) scan. However, the associated image quality by the conventional filtered back-projection (FBP) usually degrades due to the excessive quantum noise. Although sparse-view CT reconstruction algorithm via total variation (TV), in the scanning protocol of reducing X-ray tube current, has been demonstrated to be able to result in significant radiation dose reduction while maintain image quality, noticeable patchy artifacts still exist in reconstructed images. In this study, to address the problem of patchy artifacts, we proposed a median prior constrained TV regularization to retain the image quality by introducing an auxiliary vector m in register with the object. Specifically, the approximate action of m is to draw, in each iteration, an object voxel toward its own local median, aiming to improve low-dose image quality with sparse-view projection measurements. Subsequently, an alternating optimization algorithm is adopted to optimize the associative objective function. We refer to the median prior constrained TV regularization as "TV_MP" for simplicity. Experimental results on digital phantoms and clinical phantom demonstrated that the proposed TV_MP with appropriate control parameters can not only ensure a higher signal to noise ratio (SNR) of the reconstructed image, but also its resolution compared with the original TV method. pubtype: Academic Journal doctype: Journal Article ougenre: Article language: English refInfo: holdings: @attributes: islocal: N |
|---|