Hippocampal surface deformation accuracy in T1-weighted volumetric MRI sequences in subjects with epilepsy.

Background and Purpose: To demonstrate the accuracy across different acquisition and analysis methods, we evaluated the variability in hippocampal volumetric and surface displacement measurements resulting from two different MRI (magnetic resonance imaging) acquisition protocols.Methods: Nine epilep...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Neuroimaging Vol. 25; no. 3; pp. 452 - 460
Autores principales: Hogan, R Edward, Moseley, Emily D, Maccotta, Luigi
Formato: research Journal Article
Publicado: Wiley-Blackwell May2015
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=109733521&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 109733521
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        10512284
        L2W
      jtl: Journal of Neuroimaging
      issn: 10512284
      maglogo: Y
    pubinfo:
      dt: May2015
      vid: 25
      iid: 3
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        109733521
        NLM24942549
        2012997716
        10.1111/jon.12135
        NLM24942549
        PMC4272329
        109733521
      ppf: 452
      ppct: 8
      formats:
      tig:
        atl: Hippocampal surface deformation accuracy in T1-weighted volumetric MRI sequences in subjects with epilepsy.
      aug:
        au:
          Hogan, R Edward
          Moseley, Emily D
          Maccotta, Luigi
      sug:
      ab: Background and Purpose: To demonstrate the accuracy across different acquisition and analysis methods, we evaluated the variability in hippocampal volumetric and surface displacement measurements resulting from two different MRI (magnetic resonance imaging) acquisition protocols.Methods: Nine epilepsy patients underwent two independent T1-weighted magnetization prepared spoiled gradient sequences during a single 3T MRI session. Using high-dimension mapping-large deformation (HDM-LD) segmentation, we calculated volumetric estimates and generated a vector-based 3-dimensional surface model of each subject's hippocampi, and evaluated volume and surface changes, the latter using a cluster-based noise estimation model.Results: Mean hippocampal volumes and standard deviations for the left hippocampi were 2,750 (826) mm3 and 2,782 (859) mm3 (P = .13), and for the right hippocampi were 2,558 (750) mm3 and 2,547 (692) mm3 (P = .76), respectively for the MPR1 and MPR2 sequences. Average Dice coefficient comparing overlap for segmentations was 86%. There was no significant effect of MRI sequence on volume estimates and no significant hippocampal surface change between sequences.Conclusion: Statistical comparison of hippocampal volumes and statistically thresholded HDM-LD surfaces in TLE patients showed no differences between the segmentations obtained in the two MRI acquisition sequences. This validates the robustness across MRI sequences of the HDM-LD technique for estimating volume and surface changes in subjects with epilepsy.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N