Improvement of diagnostic confidence for detection of multiple myeloma involvement of the ribs by a new CT software generating rib unfolded images: Comparison with 5- and 1-mm axial images.

Objective: To investigate the performance of a new CT software generating rib unfolded images for improved detection of rib osteolyses in patients with multiple myeloma.Materials and Methods: One hundred sixteen patients who underwent whole-body reduced-dose multidetector computed tomography (WBRD-M...

Descripción completa

Detalles Bibliográficos
Publicado en:Skeletal Radiology Vol. 44; no. 7; pp. 971 - 980
Autores principales: Homann, Georg, Weisel, Katja, Mustafa, Deedar Farhad, Ditt, Hendrik, Nikolaou, Konstantin, Horger, Marius
Formato: research Journal Article
Publicado: Springer Nature Jul2015
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=109737078&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 109737078
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        03642348
        O14
      jtl: Skeletal Radiology
      issn: 03642348
      maglogo: N
    pubinfo:
      dt: Jul2015
      vid: 44
      iid: 7
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        109737078
        NLM25833276
        2013011532
        10.1007/s00256-015-2131-7
        NLM25833276
        109737078
      ppf: 971
      ppct: 9
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Improvement of diagnostic confidence for detection of multiple myeloma involvement of the ribs by a new CT software generating rib unfolded images: Comparison with 5- and 1-mm axial images.
      aug:
        au:
          Homann, Georg
          Weisel, Katja
          Mustafa, Deedar Farhad
          Ditt, Hendrik
          Nikolaou, Konstantin
          Horger, Marius
      sug:
      ab: Objective: To investigate the performance of a new CT software generating rib unfolded images for improved detection of rib osteolyses in patients with multiple myeloma.Materials and Methods: One hundred sixteen patients who underwent whole-body reduced-dose multidetector computed tomography (WBRD-MDCT) for multiple myeloma diagnosis and during follow-up were retrospectively evaluated. Nonenhanced CT scans with 5- and 1-mm slice thickness were interpreted by two readers with focus on detection of rib involvement (location, number, fracture). Image analysis of "unfolded," 1-mm-based CT rib images was subsequently undertaken. We classified the number of lytic bone lesions into 0, 1, 2, <5, <10 and ≥10. For all three data sets the reading time was registered.Results: An approximated sum of 6,727 myeloma-related rib lesions was found. On a patient-based analysis, CT (5 mm), CT (1 mm) and CT (1 mm "unfolded rib") yielded a sensitivity, specificity and accuracy of 79.7/94.7/87.1, 88.1/93/90.5 and 98.3/96.5/97.4, respectively. In a lesion-based analysis, the sensitivity, specificity and accuracy of the three evaluations were 69.7/87.2/70.5, 79.8/55.9/78 and 96.5/89.7/96.1. Mean reading time for 5 mm/1 mm axial images and unfolded images was 178.7/215.1/90.8 s, respectively.Conclusion: The generation of "unfolded rib" images improves detection of rib involvement in patients with multiple myeloma and significantly reduces reading time.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N