Nursing and midwifery practice for maintenance of vascular access device patency. A cross-sectional survey.

Background Up to 85% of hospital in-patients will require some form of vascular access device to deliver essential fluids, drug therapy, nutrition and blood products, or facilitate sampling. The failure rate of these devices is unacceptably high, with 20–69% of peripheral intravenous catheters and 1...

Descripción completa

Detalles Bibliográficos
Publicado en:International Journal of Nursing Studies Vol. 52; no. 11; pp. 1678 - 1686
Autores principales: Keogh, Samantha, Flynn, Julie, Marsh, Nicole, Higgins, Niall, Davies, Karen, Rickard, Claire M.
Formato: research Journal Article
Publicado: Elsevier B.V. Nov2015
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=109955875&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 109955875
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        00207489
        JHV
      jtl: International Journal of Nursing Studies
      issn: 00207489
      maglogo: N
    pubinfo:
      dt: Nov2015
      vid: 52
      iid: 11
      pid: 82545
      pub: Elsevier B.V.
      place: Philadelphia, Pennsylvania
    artinfo:
      ui:
        109955875
        109955875
        109955875
        10.1016/j.ijnurstu.2015.07.001
        NLM26206327
        109955875
      ppf: 1678
      ppct: 8
      formats:
      tig:
        atl: Nursing and midwifery practice for maintenance of vascular access device patency. A cross-sectional survey.
      aug:
        au:
          Keogh, Samantha
          Flynn, Julie
          Marsh, Nicole
          Higgins, Niall
          Davies, Karen
          Rickard, Claire M.
        affil: Alliance for Vascular Access Teaching and Research (AVATAR), Australia
      sug:
        subj:
          Nurse Midwifery
          Vascular Access Devices
          Catheterization, Peripheral
          Catheter Irrigation, Vascular
          Human
          Cross Sectional Studies
          Survey Research
          Nurses
          Certified Nurse Midwives
          Registered Nurses
          Adult
          Descriptive Statistics
          Central Venous Catheters
          Nurse-Midwifery Service
          Queensland
          Adult: 19-44 years
      ab: Background Up to 85% of hospital in-patients will require some form of vascular access device to deliver essential fluids, drug therapy, nutrition and blood products, or facilitate sampling. The failure rate of these devices is unacceptably high, with 20–69% of peripheral intravenous catheters and 15–66% of central venous catheters failing due to occlusion, depending on the device, setting and population. A range of strategies have been developed to maintain device patency, including intermittent flushing. However, there is limited evidence informing flushing practice and little is known about the current flushing practices. Objective The aim of the study was to improve our understanding of current flushing practices for vascular access devices through a survey of practice. Method A cross-sectional survey of nurses and midwives working in the State of Queensland, Australia was conducted using a 25-item electronic survey that was distributed via the local union membership database. Results A total of 1178 surveys were completed and analysed, with n = 1068 reporting peripheral device flushing and n = 584 reporting central device flushing. The majority of respondents were registered nurses (55%) caring for adult patients (63%). A large proportion of respondents (72% for peripheral, 742/1028; 80% for central, 451/566) were aware of their facility's policy for vascular access device flushing. Most nurses reported using sodium chloride 0.9% for flushing both peripheral (96%, 987/1028) and central devices (75%, 423/566). Some concentration of heparin saline was used by 25% of those flushing central devices. A 10-mL syringe was used by most respondents for flushing; however, 24% of respondents used smaller syringes in the peripheral device group. Use of prefilled syringes (either commercially prepared sterile or prefilled in the workplace) was limited to 10% and 11% respectively for each group. The frequency of flushing varied widely, with the most common response being pro re nata (23% peripheral and 21% central), or 6 hourly (23% peripheral and 22% central). Approximately half of respondents stated that there was no medical order or documentation for either peripheral or central device flushing. Conclusions Flushing practices for vascular access device flushing appear to vary widely. Specific areas of practice that warrant further investigation include questions about the efficacy of heparin for central device flushing, increasing adherence to the recommended 10 mL diameter syringe use, increased use of prefilled flush syringes, identifying and standardising optimal volumes and frequency of flushing, and improving documentation of flush orders and administration.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N