Assessment of image quality and low-contrast detectability in abdominal CT of obese patients: comparison of a novel integrated circuit with a conventional discrete circuit detector at different tube voltages.

Objectives: To compare image quality and low-contrast detectability of an integrated circuit (IC) detector in abdominal CT of obese patients with conventional detector technology at low tube voltages.Methods: A liver phantom with 45 lesions was placed in a water container to mimic an obese patient a...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 25; no. 3; pp. 687 - 694
Autores principales: Euler, A, Heye, T, Kekelidze, M, Bongartz, G, Szucs-Farkas, Z, Sommer, C, Schmidt, B, Schindera, Sebastian T
Formato: research Journal Article
Publicado: Springer Nature Mar2015
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=110136755&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 110136755
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: Mar2015
      vid: 25
      iid: 3
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        110136755
        NLM25316058
        2012906464
        10.1007/s00330-014-3459-4
        NLM25316058
        110136755
      ppf: 687
      ppct: 7
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Assessment of image quality and low-contrast detectability in abdominal CT of obese patients: comparison of a novel integrated circuit with a conventional discrete circuit detector at different tube voltages.
      aug:
        au:
          Euler, A
          Heye, T
          Kekelidze, M
          Bongartz, G
          Szucs-Farkas, Z
          Sommer, C
          Schmidt, B
          Schindera, Sebastian T
        affil: Clinic of Radiology and Nuclear Medicine, University of Basel Hospital, Petersgraben 4, 4031, Basel, Switzerland.
      sug:
        subj:
          Liver Neoplasms Radiography
          Obesity Radiography
          Phantoms, Imaging
          Tomography, X-Ray Computed Methods
          Aged
          Electricity
          Female
          Human
          Male
          Middle Age
          Models, Anatomic
          Radiation Dosage
          Radiographic Image Interpretation, Computer-Assisted Methods
          Sensitivity and Specificity
          Aged: 65+ years
          Middle Aged: 45-64 years
          Female
          Male
      ab: Objectives: To compare image quality and low-contrast detectability of an integrated circuit (IC) detector in abdominal CT of obese patients with conventional detector technology at low tube voltages.Methods: A liver phantom with 45 lesions was placed in a water container to mimic an obese patient and examined on two different CT systems at 80, 100 and 120 kVp. The systems were equipped with either the IC or conventional detector. Image noise was measured, and the contrast-to-noise-ratio (CNR) was calculated. Low-contrast detectability was assessed independently by three radiologists. Radiation dose was estimated by the volume CT dose index (CTDIvol).Results: The image noise was significantly lower, and the CNR was significantly higher with the IC detector at 80, 100 and 120 kVp, respectively (P = 0.023). The IC detector resulted in an increased lesion detection rate at 80 kVp (38.1 % vs. 17.2 %) and 100 kVp (57.0 % vs. 41.0 %). There was no difference in the detection rate between the IC detector at 100 kVp and the conventional detector at 120 kVp (57.0 % vs. 62.2 %). The CTDIvol at 80, 100 and 120 kVp measured 4.5-5.2, 7.3-7.9 and 9.8-10.2 mGy, respectively.Conclusions: The IC detector at 100 kVp resulted in similar low-contrast detectability compared to the conventional detector with a 120-kVp protocol at a radiation dose reduction of 37 %.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N