Shortened breath-hold contrast-enhanced MRI of the liver using a new parallel imaging technique, CAIPIRINHA (controlled aliasing in parallel imaging results in higher acceleration): a comparison with conventional GRAPPA technique.

Purpose: We examined whether the shortened breath-hold 3-dimensional volumetric interpolated breath-hold examination (3D-VIBE) sequence for high acceleration factor (AF) using the controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) could substitute for the conventiona...

Descripción completa

Detalles Bibliográficos
Publicado en:Abdominal Imaging Vol. 40; no. 8; pp. 3091 - 3099
Autores principales: Ogawa, Masaki, Kawai, Tatsuya, Kan, Hirohito, Kobayashi, Susumu, Akagawa, Yoshihiro, Suzuki, Kazushi, Nojiri, Shunsuke, Ozawa, Yoshiyuki, Shibamoto, Yuta
Formato: research Journal Article
Publicado: Springer Nature Oct2015
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=110653837&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 110653837
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09428925
        O52
      jtl: Abdominal Imaging
      issn: 09428925
      maglogo: N
    pubinfo:
      dt: Oct2015
      vid: 40
      iid: 8
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        110653837
        110653837
        NLM26099474
        110653837
        10.1007/s00261-015-0491-z
        NLM26099474
        110653837
      ppf: 3091
      ppct: 8
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Shortened breath-hold contrast-enhanced MRI of the liver using a new parallel imaging technique, CAIPIRINHA (controlled aliasing in parallel imaging results in higher acceleration): a comparison with conventional GRAPPA technique.
      aug:
        au:
          Ogawa, Masaki
          Kawai, Tatsuya
          Kan, Hirohito
          Kobayashi, Susumu
          Akagawa, Yoshihiro
          Suzuki, Kazushi
          Nojiri, Shunsuke
          Ozawa, Yoshiyuki
          Shibamoto, Yuta
        affil: Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku Nagoya 467-8601 Japan
      sug:
        subj:
          Breath Holding
          Liver Neoplasms Pathology
          Magnetic Resonance Imaging Methods
          Contrast Media
          Liver Pathology
          Image Enhancement
          Image Interpretation, Computer Assisted Methods
          Male
          Aged
          Algorithms
          Young Adult
          Imaging, Three-Dimensional
          Artifacts
          Human
          Reproducibility of Results
          Female
          Adult
          Aged, 80 and Over
          Time Factors
          Prospective Studies
          Middle Age
          Validation Studies
          Comparative Studies
          Evaluation Research
          Multicenter Studies
          Aged: 65+ years
          Adult: 19-44 years
          Aged, 80 & over
          Middle Aged: 45-64 years
          Male
          Female
      ab: Purpose: We examined whether the shortened breath-hold 3-dimensional volumetric interpolated breath-hold examination (3D-VIBE) sequence for high acceleration factor (AF) using the controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) could substitute for the conventional sequence using generalized autocalibrating partially parallel acquisition (GRAPPA) in patients undergoing routine gadoxetic acid-enhanced liver MRI.Materials and Methods: Thirty patients with clinically suspected focal liver lesions were scanned using 3D-VIBE sequences with GRAPPA with AF = 2 and AF = 4 and CAIPIRINHA with AF = 4 (acquisition times: 21, 14, and 12 s, respectively) during the hepatobiliary phase. Visual evaluations using a 3- or 5-point scale and signal-to-noise ratio (SNR) analysis were performed for the 3 sequences.Results: For CAIPIRINHA with AF = 4, there was significantly less image noise in both visual evaluation and SNR analysis and fewer parallel imaging artifacts than for GRAPPA with AF = 4 (P < 0.0005); it was equal to GRAPPA with AF = 2 and had fewer motion artifacts than GRAPPA with AF = 2 and 4 (P < 0.0012). The liver edge sharpness and hepatic vessel clarity, lesion conspicuity, and overall image quality were rated significantly higher with CAIPIRINHA with AF = 4 than GRAPPA with AF = 2 and AF = 4 (P < 0.009). For GRAPPA with AF = 4, lesion conspicuity and overall image quality were rated significantly lower than for GRAPPA with AF = 2 (P < 0.012).Conclusion: The shortened breath-hold 3D-VIBE sequence using the new CAIPIRINHA technique with a high AF of 4 was superior to the conventional GRAPPA sequence. The shortened breath-hold sequence using GRAPPA with a high AF of 4 worsened the image quality and lesion conspicuity.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N