High-resolution 3D-GRE imaging of the abdomen using controlled aliasing acceleration technique - a feasibility study.

Objectives: To assess the feasibility of high-resolution 3D-gradient-recalled echo (GRE) fat-suppressed T1-weighted images using controlled aliasing acceleration technique (CAIPIRINHA-VIBE), and compare image quality and lesion detection to standard-resolution 3D-GRE images using conventional accele...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 25; no. 12; pp. 3596 - 3606
Autores principales: AlObaidy, Mamdoh, Ramalho, Miguel, Busireddy, Kiran, Liu, Baodong, Burke, Lauren, Altun, Ersan, Dale, Brian, Semelka, Richard, Busireddy, Kiran K R, Burke, Lauren M, Dale, Brian M, Semelka, Richard C
Formato: diagnostic images research tables/charts Journal Article
Publicado: Springer Nature Dec2015
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=110814247&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 110814247
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: Dec2015
      vid: 25
      iid: 12
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        110814247
        110814247
        NLM25916391
        110814247
        10.1007/s00330-015-3780-6
        NLM25916391
        110814247
      ppf: 3596
      ppct: 10
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: High-resolution 3D-GRE imaging of the abdomen using controlled aliasing acceleration technique - a feasibility study.
      aug:
        au:
          AlObaidy, Mamdoh
          Ramalho, Miguel
          Busireddy, Kiran
          Liu, Baodong
          Burke, Lauren
          Altun, Ersan
          Dale, Brian
          Semelka, Richard
          Busireddy, Kiran K R
          Burke, Lauren M
          Dale, Brian M
          Semelka, Richard C
        affil: Department of Radiology, University of North Carolina at Chapel Hill, CB 7510-2001 Old Clinic Bldg. Chapel Hill 27599-7510 USA
      sug:
        subj:
          Imaging, Three-Dimensional Methods
          Magnetic Resonance Imaging Methods
          Abdomen Pathology
          Aged, 80 and Over
          Adult
          Reproducibility of Results
          Motion
          Pilot Studies
          Contrast Media
          Female
          Artifacts
          Middle Age
          Breath Holding
          Young Adult
          Male
          Adolescence
          Aged
          Human
          Aged, 80 & over
          Adult: 19-44 years
          Middle Aged: 45-64 years
          Adolescent: 13-18 years
          Aged: 65+ years
          Female
          Male
      ab: Objectives: To assess the feasibility of high-resolution 3D-gradient-recalled echo (GRE) fat-suppressed T1-weighted images using controlled aliasing acceleration technique (CAIPIRINHA-VIBE), and compare image quality and lesion detection to standard-resolution 3D-GRE images using conventional acceleration technique (GRAPPA-VIBE).Materials and Methods: Eighty-four patients (41 males, 43 females; age range: 14-90 years, 58.8 ± 15.6 years) underwent abdominal MRI at 1.5 T with CAIPIRINHA-VIBE [spatial resolution, 0.76 ± 0.04 mm] and GRAPPA-VIBE [spatial resolution, 1.17 ± 0.14 mm]. Two readers independently reviewed image quality, presence of artefacts, lesion conspicuity, and lesion detection. Kappa statistic was used to assess interobserver agreement. Wilcoxon signed-rank test was used for image qualitative pairwise comparisons. Logistic regression with post-hoc testing was used to evaluate statistical significance of lesions evaluation.Results: Interobserver agreement ranged between 0.45-0.93. Pre-contrast CAIPIRINHA-VIBE showed significantly (p < 0.001) sharper images and lesion conspicuity with decreased residual aliasing, but more noise enhancement and inferior image quality. Post-contrast CAIPIRINHA-VIBE showed significantly (p < 0.001) sharper images and higher lesion conspicuity, with less respiratory motion and residual aliasing artefacts. Inferior fat-suppression was noticeable on CAIPIRINHA-VIBE sequences (p < 0.001).Conclusion: High in-plane resolution abdominal 3D-GRE fat-suppressed T1-weighted imaging using controlled-aliasing acceleration technique is feasible and yields sharper images compared to standard-resolution images using standard acceleration, with higher post-contrast image quality and trend for improved hepatic lesions detection.Key Points: • High-resolution imaging of the upper abdomen is clinically feasible using 2D-controlled aliasing acceleration technique. • High-resolution imaging yields significantly sharper images and increased hepatic lesions conspicuity. • High-resolution imaging yields significantly less respiratory motion and residual aliasing artefacts. • Controlled-aliasing offers substantial acquisition-time reduction in patients with breath-holding difficulties.
      pubtype: Academic Journal
      doctype:
        diagnostic images
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N