Value of C-Arm Computed Tomography to Evaluate Stent Deployment During Femoro-Popliteal Revascularization.

Purpose: To compare the accuracy of C-arm computed tomography (CT) and digital subtraction angiography (DSA) in detecting incomplete stent expansion (ISE) after superficial femoral artery (SFA) stenting using intravascular ultrasound (IVUS) as a gold standard.Materials: Fifty patients with symptomat...

Descripción completa

Detalles Bibliográficos
Publicado en:CardioVascular & Interventional Radiology Vol. 38; no. 6; pp. 1458 - 1468
Autores principales: Gahide, Gerald, Hadjadj, Sofiane, Therasse, Eric, Kauffmann, Claude, Gilbert, Patrick, Oliva, Vincent, Tardif, Jean-Claude, Lespérance, Jacques, Cloutier, Guy, Soulez, Gilles, Oliva, Vincent L
Formato: research randomized controlled trial Journal Article
Publicado: Springer Nature Dec2015
Acceso en línea:Ver este registro en EBSCOhost
Descripción
Sumario:Purpose: To compare the accuracy of C-arm computed tomography (CT) and digital subtraction angiography (DSA) in detecting incomplete stent expansion (ISE) after superficial femoral artery (SFA) stenting using intravascular ultrasound (IVUS) as a gold standard.Materials: Fifty patients with symptomatic SFA occlusive disease requiring angioplasty were prospectively included. Once technical success (<30 % residual stenosis) was obtained on post-procedural DSA, C-arm CT and IVUS were acquired. DSA and C-arm CT examinations were reviewed by 2 investigators and correlated with IVUS. C-arm CT image quality was rated on a four-point scale. Doppler ultrasound was performed at 1-year follow-up.Results: The ankle-brachial index was 0.69 ± 0.10 and 0.99 ± 0.40, respectively, pre- and post-procedure. C-arm CT imaging quality was rated as good or excellent in 80%. In-stent minimal luminal diameter (MLD) was evaluated at 4.71 ± 0.7 mm on DSA, 3.39 ± 0.6 mm on IVUS, and 3.12 ± 0.9 mm on C-arm CT. Compared to IVUS, DSA demonstrated an overestimation of MLD (p = 0.0001), an underestimation of ISE (DSA = 18.8% ± 7.6; IVUS = 29.8% ± 9) (p < 0.0001), and a poor inter-technique intra-class correlation coefficient (ICC = 0.24). No difference was observed between IVUS and C-arm CT in ISE as calculated by diameter (29.8 ± 9 vs. 28.2 ± 12.5%, p = 0.5) and area (30.2 ± 8.4 vs. 33.3 ± 9.5%, p = 0.2). Inter-technique ICC between C-arm CT and IVUS was 0.72 [95%CI 0.49; 0.85] for MLA measurements. The inter-observer ICC for MLD and MLA measurements on C-arm CT were, respectively, estimated at 0.75 [95% CI 0.40, 0.89] and 0.77 [95% CI 0.43, 0.90)].Conclusions: C-arm CT presents a better correlation with IVUS than DSA to determine lumen diameter and ISE immediately after percutaneous revascularization.