Creatinuria predicha de la densidad urinaria como el denominador del índice de excreción de una sustancia.

Rationale: Accuracy of the urinary concentration of a substance as predicted from index of excretion IndEx = C/OCre critically relies upon OCre: creatinine urinary concentration. OCre can be stocastically approximated from urinary density (D). Objective: To assess clinical and diagnostic usefulness...

Descripción completa

Detalles Bibliográficos
Publicado en:Revista Mexicana de Patología Clínica y Medicina de Laboratorio Vol. 62; no. 4; pp. 220 - 230
Autores principales: Salabarría González, José Reynaldo, Porbén, Sergio Santana, Liriano Ricabal, María del Rosario
Formato: Artículo
Publicado: Federacion Mexicana de Patologia Clinica y de la Asociacion Latinoamericana de Patologia Clinica 2015
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=lth&AN=111060973&site=ehost-live
header:
  @attributes:
    shortDbName: lth
    uiTerm: 111060973
    longDbName: MedicLatina
    uiTag: AN
  controlInfo:
    bkinfo:
    jinfo:
      jid:
        01856014
        FXKA
      jtl: Revista Mexicana de Patología Clínica y Medicina de Laboratorio
      issn: 01856014
      maglogo: N
    pubinfo:
      dt: 2015
      vid: 62
      iid: 4
      pid: 20868
      pub: Federacion Mexicana de Patologia Clinica y de la Asociacion Latinoamericana de Patologia Clinica
    artinfo:
      ui: 111060973
      ppf: 220
      ppct: 10
      formats:
        fmt:
          @attributes:
            type: P
            size: 1.5MB
      tig:
        atl: Creatinuria predicha de la densidad urinaria como el denominador del índice de excreción de una sustancia.
      aug:
        au:
          Salabarría González, José Reynaldo
          Porbén, Sergio Santana
          Liriano Ricabal, María del Rosario
        affil:
          Médico, Especialista de segundo grado en Laboratorio Clínico. Profesor Auxiliar de Laboratorio Clínico. Hospital Pediátrico Universitario «Juan Manuel Márquez». La Habana, Cuba
          Médico, Especialista de segundo grado en Bioquímica Clínica. Máster en Nutrición en Salud Pública. Profesor Asistente de Bioquímica. Hospital Clínico Quirúrgico «Hermanos Ameijeiras». La Habana, Cuba
          Médico, Especialista de primer grado en Laboratorio Clínico. Profesor Asistente de Laboratorio Clínico. Hospital Pediátrico Universitario «Juan Manuel Márquez». La Habana, Cuba
      sug:
      keyword:
        creatinine
        index of excretion
        urinary concentration
        Urine density
        índice de excreción
        concentración urinaria
        creatinina
        creatinine
        Densidad urinaria
        index of excretion
        urinary concentration
        Urine density
      ab:
        Rationale: Accuracy of the urinary concentration of a substance as predicted from index of excretion IndEx = C/OCre critically relies upon OCre: creatinine urinary concentration. OCre can be stocastically approximated from urinary density (D). Objective: To assess clinical and diagnostic usefulness of the urinary concentration of a substance when OCre as predicted from D is used as denominator of IndEx. Material and methods: Values of D, OCre and concentrations Csust of the substance of interest (sust = total proteins, albumin, calcium, magnesium, uric acid) obtained in urine samples collected from children of either sex, with ages between 1-19 years, assisted at the Urine Section, Clinical Laboratory Service, «Juan Manuel Márquez» Pediatric Teaching Hospital (Havana City, Cuba), between 2009-2014, were recovered. ... = a + b*D, with D = (D-1)*100 was used as denominator of IndEx. Results: Analytical accuracy (estimated from the slope of method-comparisons straight line) was more than 80% within the range of concentrations of interest of the substance. Frequency of abnormal values was similar to any of the strategies used in calculating urinary excretion of the substance. Conclusions: Use of OCre as predicted from urine density can be an effective strategy for calculating urinary concentration of a substance as an alternative instead of studies currently done with 24 hours-collections.
        Justificación: La exactitud de la concentración urinaria de una sustancia predicha del índice de excreción IndEx = C/OCre depende críticamente de OCre: la concentración urinaria de creatinina. OCre puede aproximarse estocásticamente de la densidad urinaria (D). Objetivo: Evaluar la utilidad clínica y diagnóstica de la concentración urinaria de una sustancia cuando OCre predicha de D se emplea como denominador de IndEx. Material y métodos: Se recuperaron los valores de D, OCre y de las concentraciones Csust de la sustancia de interés (sust = proteínas totales, albúmina, calcio, magnesio, uratos) determinadas en muestras de orina de los niños de uno u otro sexo, con edades entre 1 y19 años, atendidos en la Sección de Orina del Servicio de Laboratorio Clínico del Hospital Pediátrico Universitario «Juan Manuel Márquez» (La Habana, Cuba), entre 2009 y 2014. El término ... = a + b*D, con D = (D-1)*100 se empleó como el denominador de IndEx. Resultados: La exactitud analítica (medida de la pendiente de la recta de comparación de métodos) fue mayor de 80% en el rango de las concentraciones de interés de la sustancia. La frecuencia de valores anómalos fue similar a cualquiera de las estrategias empleadas en el cálculo de la excreción urinaria de la sustancia. Conclusiones: El uso de OCre predicha de la densidad urinaria puede ser una estrategia efectiva para el cálculo de la concentración urinaria de una sustancia en sustitución de los estudios hechos con colecciones de 24 horas.
      pubtype: Academic Journal
      doctype: Article
      src: R
    language: Spanish
    refInfo:
    copyright:
      @attributes:
        flag: Y
      custom: Copyright of Revista Mexicana de Patología Clínica y Medicina de Laboratorio is the property of Federacion Mexicana de Patologia Clinica y de la Asociacion Latinoamericana de Patologia Clinica and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use.
      item: Revista Mexicana de Patología Clínica y Medicina de Laboratorio
      holder: Federacion Mexicana de Patologia Clinica y de la Asociacion Latinoamericana de Patologia Clinica
      dt:
        @attributes:
          year: 2015
    holdings:
      @attributes:
        islocal: N