Post-deployment usability evaluation of a radiology workstation.

Objectives: To determine the number, nature and severity of usability issues radiologists encounter while using a commercially available radiology workstation in clinical practice, and to assess how well the results of a pre-deployment usability evaluation of this workstation generalize to clinical...

Full description

Bibliographic Details
Published in:International Journal of Medical Informatics Vol. 85; no. 1; pp. 28 - 36
Main Authors: Jorritsma, Wiard, Cnossen, Fokie, Dierckx, Rudi A., Oudkerk, Matthijs, Van Ooijen, Peter M.A.
Format: research Journal Article
Published: Elsevier B.V. Jan2016
Online Access:View this record in EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=111568363&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 111568363
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        13865056
        JR4
      jtl: International Journal of Medical Informatics
      issn: 13865056
      maglogo: N
    pubinfo:
      dt: Jan2016
      vid: 85
      iid: 1
      pid: 467
      pub: Elsevier B.V.
      place: New York, New York
    artinfo:
      ui:
        111568363
        111568363
        NLM26574242
        111568363
        10.1016/j.ijmedinf.2015.11.001
        NLM26574242
        111568363
      ppf: 28
      ppct: 8
      formats:
      tig:
        atl: Post-deployment usability evaluation of a radiology workstation.
      aug:
        au:
          Jorritsma, Wiard
          Cnossen, Fokie
          Dierckx, Rudi A.
          Oudkerk, Matthijs
          Van Ooijen, Peter M.A.
        affil: University of Groningen, University Medical Center Groningen, Dept. Radiology, Hanzeplein 1, 9713 GZ Groningen, The Netherlands
      sug:
        subj:
          Specialties, Medical Equipment and Supplies
          Job Satisfaction
          Computer Terminals
          Human
          Validation Studies
          Comparative Studies
          Evaluation Research
          Multicenter Studies
      ab: Objectives: To determine the number, nature and severity of usability issues radiologists encounter while using a commercially available radiology workstation in clinical practice, and to assess how well the results of a pre-deployment usability evaluation of this workstation generalize to clinical practice.Methods: The usability evaluation consisted of semi-structured interviews and observations of twelve users using the workstation during their daily work. Usability issues and positive usability findings were documented. Each issue was given a severity rating and its root cause was determined. Results were compared to the results of a pre-deployment usability evaluation of the same workstation.Results: Ninety-two usability issues were identified, ranging from issues that cause minor frustration or delay, to issues that cause significant delays, prevent users from completing tasks, or even pose a potential threat to patient safety. The results of the pre-deployment usability evaluation had limited generalizability to clinical practice.Conclusions: This study showed that radiologists encountered a large number and a wide variety of usability issues when using a commercially available radiology workstation in clinical practice. This underlines the need for effective usability engineering in radiology. Given the limitations of pre-deployment usability evaluation in radiology, which were confirmed by our finding that the results of a pre-deployment usability evaluation of this workstation had limited generalizability to clinical practice, it is vital that radiology workstation vendors devote significant resources to usability engineering efforts before deployment of their workstation, and to continue these efforts after the workstation is deployed in a hospital.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N