Functional gadoxetate disodium-enhanced MRI in patients with primary sclerosing cholangitis (PSC).

Objectives: To assess the value of variable flip angle-based T1 liver mapping on gadoxetate disodium-enhanced MRI in patients with primary sclerosing cholangitis (PSC) for evaluation of global and segmental liver function, and determine a possible correlation with disease severity.Methods: Sixty-one...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 26; no. 4; pp. 1116 - 1125
Autores principales: Hinrichs, Heiko, Hinrichs, Jan, Gutberlet, Marcel, Lenzen, Henrike, Raatschen, Hans-Juergen, Wacker, Frank, Ringe, Kristina, Hinrichs, Jan B, Ringe, Kristina I
Formato: diagnostic images research tables/charts Journal Article
Publicado: Springer Nature Apr2016
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=113486847&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 113486847
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: Apr2016
      vid: 26
      iid: 4
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        113486847
        113486847
        NLM26205638
        113486847
        10.1007/s00330-015-3913-y
        NLM26205638
        113486847
      ppf: 1116
      ppct: 9
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Functional gadoxetate disodium-enhanced MRI in patients with primary sclerosing cholangitis (PSC).
      aug:
        au:
          Hinrichs, Heiko
          Hinrichs, Jan
          Gutberlet, Marcel
          Lenzen, Henrike
          Raatschen, Hans-Juergen
          Wacker, Frank
          Ringe, Kristina
          Hinrichs, Jan B
          Ringe, Kristina I
        affil: Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg Str. 1 30625 Hannover Germany
      sug:
        subj:
          Cholangitis, Sclerosing Pathology
          Contrast Media
          Magnetic Resonance Imaging Methods
          Image Enhancement Methods
          Female
          Middle Age
          Adult
          Male
          Liver Pathology
          Aged
          Young Adult
          Prospective Studies
          Reproducibility of Results
          Liver Function Tests
          Human
          Middle Aged: 45-64 years
          Adult: 19-44 years
          Aged: 65+ years
          Female
          Male
      ab: Objectives: To assess the value of variable flip angle-based T1 liver mapping on gadoxetate disodium-enhanced MRI in patients with primary sclerosing cholangitis (PSC) for evaluation of global and segmental liver function, and determine a possible correlation with disease severity.Methods: Sixty-one patients (19 female, 42 male; mean age 41 years) with PSC were included in this prospective study. T1 mapping was performed using a 3D-spoiled GRE sequence (flip angles 5°, 15°, 20°, 30°) before, 16 (HP1) and 132 min (HP2) after contrast injection. T1 values were measured and compared (Wilcoxon-Test) by placing ROIs in each liver segment. The mean reduction of T1 relaxation time at HP1 and HP2 was calculated and correlated with liver function tests (LFTs), MELD, Mayo Risk and Amsterdam Scores (Spearman correlation).Results: Significant changes of T1 relaxation times between non-enhanced and gadoxetate disodium-enhanced MRI at HP1 and HP2 could be observed in all liver segments (p < 0.0001). A significant correlation of T1 reduction could be observed with LFTs, MELD and Mayo Risk Score (p < 0.05).Conclusions: T1 mapping of the liver using a variable flip angle-based sequence is a feasible technique to evaluate liver function on a global level, and may be extrapolated on a segmental level in patients with PSC.Key Points: • T1 mapping enables evaluation of global liver function in PSC. • T1 relaxation time reduction correlates with the MELD and MayoRisk Score. • Extrapolated, T1 mapping may allow for segmental evaluation of liver function.
      pubtype: Academic Journal
      doctype:
        diagnostic images
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N