Reliability and measurement error of frontal and horizontal 3D spinal motion parameters in 219 patients with chronic low back pain.

Background: In order for measurements to be clinically useful, data on psychometric conditions such as reliability should be available in the population for which the measurements are intended to be used. This study comprises a test-retest design separated by 7 to 14 days, and evaluates the intra an...

Descripción completa

Detalles Bibliográficos
Publicado en:Chiropractic & Manual Therapies Vol. 24; pp. 1 - 11
Autores principales: Harsted, Steen, Mieritz, Rune M., Bronfort, Gert, Hartvigsen, Jan
Formato: research tables/charts Journal Article
Publicado: BioMed Central 4/4/2016
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=114503313&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 114503313
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        2045709X
        BG1Z
      jtl: Chiropractic & Manual Therapies
      issn: 2045709X
      maglogo: N
    pubinfo:
      dt: 4/4/2016
      vid: 24
      pid: 24147
      pub: BioMed Central
    artinfo:
      ui:
        114503313
        114503313
        114503313
        10.1186/s12998-016-0092-0
        114503313
      ppf: 1
      ppct: 10
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Reliability and measurement error of frontal and horizontal 3D spinal motion parameters in 219 patients with chronic low back pain.
      aug:
        au:
          Harsted, Steen
          Mieritz, Rune M.
          Bronfort, Gert
          Hartvigsen, Jan
        affil: Institute of Sports Science and Clinical Biomechanics, University of Southern Denmark, Campusvej 55, Odense M DK-5230, Denmark
      sug:
        subj:
          Low Back Pain
          Measurement Error
          Interrater Reliability Evaluation
          Intrarater Reliability Evaluation
          Range of Motion Evaluation
          Chronic Pain
          Human
          Male
          Female
          Funding Source
          Test-Retest Reliability
          Kinematics
          Intraclass Correlation Coefficient
          Models, Theoretical
          Body Mass Index
          Motion Analysis Systems Utilization
          Biomechanics
          Convenience Sample
          Randomized Controlled Trials
          Academic Medical Centers Minnesota
          Minnesota
          Adolescence
          Adult
          Middle Age
          Young Adult
          Aged
          Questionnaires
          Descriptive Statistics
          Data Analysis Software
          Confidence Intervals
          Paired T-Tests
          Range of Motion Physiology
          Comparative Studies
          Correlation Coefficient
          Adolescent: 13-18 years
          Adult: 19-44 years
          Middle Aged: 45-64 years
          Aged: 65+ years
          Male
          Female
      ab: Background: In order for measurements to be clinically useful, data on psychometric conditions such as reliability should be available in the population for which the measurements are intended to be used. This study comprises a test-retest design separated by 7 to 14 days, and evaluates the intra and interrater reliability of regional frontal and horizontal spinal motion in 219 chronic LBP patients using the CA6000 Spine Motion Analyzer. In addition, it compares these results on the frontal and horizontal plane with previously published results on the sagittal plane. 219 individuals with chronic mechanical LBP, classified as either Quebec Task Force group 1, 2, 3 or 4 were included, and kinematics of the lumbar spine were sampled during standardized spinal lateral flexion and rotation motion using a 6-df instrumented spatial linkage system. Test-retest reliability and measurement error were evaluated using intraclass correlation coefficients ICC(1,1) and Bland-Altman limits of agreement (LOAs). Results: The reliability analysis based on the whole study sample showed ICC(1,1) coefficients varying between 0.68 and 0.73 for the frontal plane and 0.33 and 0.49 for the horizontal plane. Relatively wide LOAs were observed for all parameters. Reliability measures in patient subgroups ICC(1,1) ranged between 0.55 and 0.81 for the frontal plane and 0.28 and 0.69 for the horizontal plane. Greater ICC(1,1) coefficients and smaller LOA were observed when patients were examined by the same examiner, had a stable pain level between tests, and were male. ROM measurements were more reliable in patients with a BMI higher than 30, and measurements on patients with LBP and leg pain showed higher reliability and smaller measurement error in all parameters except for the jerk index. Conclusion: Frontal plane measurements obtained using the CA6000 Spine Motion Analyzer are sufficiently reliable to be used for group comparisons but not individual comparisons. Measurements in the horizontal plane can be used for neither group nor individual comparisons.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N