Reliable and Accurate Calcium Volume Measurement in Coronary Artery Using Intravascular Ultrasound Videos.

Quantitative assessment of calcified atherosclerotic volume within the coronary artery wall is vital for cardiac interventional procedures. The goal of this study is to automatically measure the calcium volume, given the borders of coronary vessel wall for all the frames of the intravascular ultraso...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Medical Systems Vol. 40; no. 3; pp. 1 - 21
Autores principales: Araki, Tadashi, Banchhor, Sumit, Londhe, Narendra, Ikeda, Nobutaka, Radeva, Petia, Shukla, Devarshi, Saba, Luca, Balestrieri, Antonella, Nicolaides, Andrew, Shafique, Shoaib, Laird, John, Suri, Jasjit
Formato: diagnostic images equations & formulas pictorial research tables/charts Journal Article
Publicado: Springer Nature Mar2016
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=115925274&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 115925274
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01485598
        4N0
      jtl: Journal of Medical Systems
      issn: 01485598
      maglogo: N
    pubinfo:
      dt: Mar2016
      vid: 40
      iid: 3
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        115925274
        115925274
        115925274
        10.1007/s10916-015-0407-z
        115925274
      ppf: 1
      ppct: 20
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Reliable and Accurate Calcium Volume Measurement in Coronary Artery Using Intravascular Ultrasound Videos.
      aug:
        au:
          Araki, Tadashi
          Banchhor, Sumit
          Londhe, Narendra
          Ikeda, Nobutaka
          Radeva, Petia
          Shukla, Devarshi
          Saba, Luca
          Balestrieri, Antonella
          Nicolaides, Andrew
          Shafique, Shoaib
          Laird, John
          Suri, Jasjit
        affil: Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, Tokyo Japan
      sug:
        subj:
          Cardiology
          Coronary Arteriosclerosis
          Intravascular Space Ultrasonography
          Calcium Physiology
          Calcium Analysis
          Computing Methodologies
          Reliability
          Human
          Descriptive Statistics
          T-Tests
          Angina Pectoris
          Female
          Male
          Adult
          Middle Age
          Aged
          Aged, 80 and Over
          Algorithms
          Adult: 19-44 years
          Middle Aged: 45-64 years
          Aged: 65+ years
          Aged, 80 & over
          Female
          Male
      ab: Quantitative assessment of calcified atherosclerotic volume within the coronary artery wall is vital for cardiac interventional procedures. The goal of this study is to automatically measure the calcium volume, given the borders of coronary vessel wall for all the frames of the intravascular ultrasound (IVUS) video. Three soft computing fuzzy classification techniques were adapted namely Fuzzy c-Means (FCM), K-means, and Hidden Markov Random Field (HMRF) for automated segmentation of calcium regions and volume computation. These methods were benchmarked against previously developed threshold-based method. IVUS image data sets (around 30, 600 IVUS frames) from 15 patients were collected using 40 MHz IVUS catheter (Atlantis® SR Pro, Boston Scientific®, pullback speed of 0.5 mm/s). Calcium mean volume for FCM, K-means, HMRF and threshold-based method were 37.84 ± 17.38 mm, 27.79 ± 10.94 mm, 46.44 ± 19.13 mm and 35.92 ± 16.44 mm respectively. Cross-correlation, Jaccard Index and Dice Similarity were highest between FCM and threshold-based method: 0.99, 0.92 ± 0.02 and 0.95 + 0.02 respectively. Student's t-test, z-test and Wilcoxon-test are also performed to demonstrate consistency, reliability and accuracy of the results. Given the vessel wall region, the system reliably and automatically measures the calcium volume in IVUS videos. Further, we validated our system against a trained expert using scoring: K-means showed the best performance with an accuracy of 92.80 %. Out procedure and protocol is along the line with method previously published clinically.
      pubtype: Academic Journal
      doctype:
        diagnostic images
        equations & formulas
        pictorial
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N