Alteraciones de la estructura de la lima primaria posterior a su uso.

Objective: To analyze structural changes of WaveOne® (Dentsply, Maillefer®) primary files (M-Wire alloy) after preparation of an upper first molar mv1 canal and subsequent sterilization. Methods: Analysis included 2 new (group 1) and 6 used and sterilized files (group 2) that were used to prepare th...

Descripción completa

Detalles Bibliográficos
Publicado en:Universitas Odontológica Vol. 34; no. 73; pp. 14 - 26
Autores principales: Gutiérrez Barreto, Javier Fernando, Cajamarca Medina, Diana Carolina, Monroy Navas, Johanna Carolina
Formato: Artículo
Publicado: Pontificia Universidad Javeriana 2015
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=lth&AN=115953043&site=ehost-live
header:
  @attributes:
    shortDbName: lth
    uiTerm: 115953043
    longDbName: MedicLatina
    uiTag: AN
  controlInfo:
    bkinfo:
    jinfo:
      jid:
        01204319
        B7PV
      jtl: Universitas Odontológica
      issn: 01204319
      maglogo: N
    pubinfo:
      dt: 2015
      vid: 34
      iid: 73
      pid: 22324
      pub: Pontificia Universidad Javeriana
    artinfo:
      ui: 115953043
      ppf: 14
      ppct: 12
      formats:
        fmt:
          @attributes:
            type: P
            size: 596KB
      tig:
        atl: Alteraciones de la estructura de la lima primaria posterior a su uso.
      aug:
        au:
          Gutiérrez Barreto, Javier Fernando
          Cajamarca Medina, Diana Carolina
          Monroy Navas, Johanna Carolina
        affil:
          Odontólogo, Universidad Nacional de Colombia, Especialista en Endodoncia, Docente Posgrado de Endodoncia, Universidad Santo Tomas. Bogotá, Colombia
          Odontóloga, Universidad Nacional de Colombia. Especialista en Endodoncia, Universidad Santo Tomas. Bogotá, Colombia
          Odontóloga, Pontificia Universidad Javeriana. Especialista en Endodoncia, Universidad Santo Tomas. Bogotá, Colombia
      sug:
      keyword:
        Austenite
        M-Wire
        martensite
        phase R
        transformation ranges
        Alambre M
        austenita
        fase R
        martensita
        rangos de transformación
      ab:
        Objective: To analyze structural changes of WaveOne® (Dentsply, Maillefer®) primary files (M-Wire alloy) after preparation of an upper first molar mv1 canal and subsequent sterilization. Methods: Analysis included 2 new (group 1) and 6 used and sterilized files (group 2) that were used to prepare the mesial buccal root canal of maxillary molars with moderate curvature. Structure was evaluated through X-ray diffractometry, Results: No instrument broke during canal preparation. X-ray diffraction patterns for group 1 showed 3 main peaks with similar intensity, the same width, and 2. position. Group 2 files showed intensity increases after using them once and peak and width stayed stable afterwards in most samples. Contradictory to this behavior was shown that two samples after being used sterilized and did not show this pattern, showing low intensity peaks. Conclusion: WaveOne® primary file with M-Wire alloy showed an increase of intensity inn every phases and same number of peaks, which suggests no damage in the alloy.
        Objetivo: Analizar las alteraciones en la estructura de las limas primarias con aleación alambre M del sistema WaveOne® (Dentsply, Maillefer®) después de la preparación del conducto mv1 de un primer molar superior y su posterior esterilización, analizadas mediante la técnica de difractometría de rayos X. Métodos: Se evaluaron 2 limas nuevas (grupo 1) y 6 limas usadas y esterilizadas (grupo 2) que fueron empleadas para preparar el conducto mv1 de molares superiores en pacientes que presentaban curvatura moderada. Resultados: Durante la preparación del conducto radicular no se presentó fractura de ningún instrumento. Los patrones de difracción de rayos X del grupo 1 mostraron tres picos principales con similar intensidad, el mismo ancho y posición 2.. El comportamiento de la mayoría de las limas pertenecientes al grupo 2 exhibió un incremento de sus intensidades posterior a su uso preservando la posición y ancho del pico en las diferentes muestras. Conclusiones: La lima primaria del sistema WaveOne® con aleación alambre M mostró un aumento en la intensidad de sus fases sin variación en la cantidad de picos, situación que sugiere que no se presenta daño en la aleación.
      pubtype: Academic Journal
      doctype: Article
      src: R
    language: Spanish
    refInfo:
    copyright:
      @attributes:
        flag: Y
      custom: Copyright of Universitas Odontológica is the property of Pontificia Universidad Javeriana and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use.
      item: Universitas Odontológica
      holder: Pontificia Universidad Javeriana
      dt:
        @attributes:
          year: 2015
    holdings:
      @attributes:
        islocal: N