Novel application of chemical shift gradient echo in- and opposed-phase sequences in 3 T MRI for the detection of H-MRS visible lipids and grading of glioma.

Objectives: We evaluated the feasibility of using chemical shift gradient-echo (GE) in- and opposed-phase (IOP) imaging to grade glioma.Methods: A phantom study was performed to investigate the correlation of (1)H MRS-visible lipids with the signal loss ratio (SLR) obtained using IOP imaging. A cros...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 26; no. 7; pp. 2019 - 2030
Autores principales: Ramli, Norlisah, Khairy, Azua, Seow, Pohchoo, Tan, Li, Wong, Jeannie, Ganesan, Dharmendra, Rahmat, Kartini, Khairy, Azua Mohd, Tan, Li Kuo, Wong, Jeannie Hsiu Ding
Formato: diagnostic images pictorial research tables/charts Journal Article
Publicado: Springer Nature Jul2016
Acceso en línea:Ver este registro en EBSCOhost
Descripción
Sumario:Objectives: We evaluated the feasibility of using chemical shift gradient-echo (GE) in- and opposed-phase (IOP) imaging to grade glioma.Methods: A phantom study was performed to investigate the correlation of (1)H MRS-visible lipids with the signal loss ratio (SLR) obtained using IOP imaging. A cross-sectional study approved by the institutional review board was carried out in 22 patients with different glioma grades. The patients underwent scanning using IOP imaging and single-voxel spectroscopy (SVS) using 3T MRI. The brain spectra acquisitions from solid and cystic components were obtained and correlated with the SLR for different grades.Results: The phantom study showed a positive linear correlation between lipid quantification at 0.9 parts per million (ppm) and 1.3 ppm with SLR (r = 0.79-0.99, p < 0.05). In the clinical study, we found that SLR at the solid portions was the best measure for differentiating glioma grades using optimal cut-points of 0.064 and 0.086 with classification probabilities for grade II (SII = 1), grade III (SIII = 0.50) and grade IV (SIV = 0.89).Conclusions: The results underscore the lipid quantification differences in grades of glioma and provide a more comprehensive characterization by using SLR in chemical shift GE IOP imaging. SLR in IOP sequence demonstrates good performance in glioma grading.Key Points: • Strong correlation was seen between lipid concentration and SLR obtained using IOP • IOP sequence demonstrates significant differences in signal loss within the glioma grades • SLR at solid tumour portions was the best measure for differentiation • This sequence is applicable in a research capacity for glioma staging armamentarium.