An Automatic Algorithm Based on Morphological Stability During Fast Ventricular Arrhythmias Predicts Successful Antitachycardia Pacing in ICD Patients: A Multicenter Study.

Background Different types of ventricular arrhythmias (monomorphic ventricular tachycardia [VT], polymorphic VT, or ventricular fibrillation) can be detected by implantable cardiac defibrillators (ICDs) in fast VT zone. The efficacy of antitachycardia pacing (ATP) depends on the type of the treated...

Descripción completa

Detalles Bibliográficos
Publicado en:Pacing & Clinical Electrophysiology Vol. 39; no. 7; pp. 633 - 642
Autores principales: MATÍA, ROBERTO, HERNÁNDEZ ‐ MADRID, ANTONIO, SÁNCHEZ ‐ HUETE, GONZALO, MARTÍNEZ ‐ FERRER, JOSÉ BAUTISTA, ALZUETA, JAVIER, VIÑOLAS, XAVIER, RUBIO, JERÓNIMO, PORRES, JOSÉ MANUEL, RODRÍGUEZ, ANÍBAL, GARCÍA, ENRIQUE, FERNÁNDEZ ‐ LOZANO, IGNACIO, ÁLVAREZ, MIGUEL, MORENO, JAVIER
Formato: algorithm equations & formulas research tables/charts tracings Journal Article
Publicado: Wiley-Blackwell Jul2016
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=116618020&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 116618020
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01478389
        4F8
      jtl: Pacing & Clinical Electrophysiology
      issn: 01478389
      maglogo: Y
    pubinfo:
      dt: Jul2016
      vid: 39
      iid: 7
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        116618020
        116618020
        116618020
        10.1111/pace.12858
        116618020
      ppf: 633
      ppct: 9
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: An Automatic Algorithm Based on Morphological Stability During Fast Ventricular Arrhythmias Predicts Successful Antitachycardia Pacing in ICD Patients: A Multicenter Study.
      aug:
        au:
          MATÍA, ROBERTO
          HERNÁNDEZ ‐ MADRID, ANTONIO
          SÁNCHEZ ‐ HUETE, GONZALO
          MARTÍNEZ ‐ FERRER, JOSÉ BAUTISTA
          ALZUETA, JAVIER
          VIÑOLAS, XAVIER
          RUBIO, JERÓNIMO
          PORRES, JOSÉ MANUEL
          RODRÍGUEZ, ANÍBAL
          GARCÍA, ENRIQUE
          FERNÁNDEZ ‐ LOZANO, IGNACIO
          ÁLVAREZ, MIGUEL
          MORENO, JAVIER
        affil: Arrhythmia Unit, Cardiology Department, Ramón y Cajal Hospital, Madrid Spain
      sug:
        subj:
          Algorithms
          Cardiac Pacing, Artificial
          Defibrillators, Implantable
          Heart Ventricle Anatomy and Histology
          Tachycardia, Ventricular
          Human
          Electrocardiography
          Descriptive Statistics
          Data Analysis Software
          Odds Ratio
          Confidence Intervals
          Observational Methods
          Prospective Studies
          Retrospective Design
          Funding Source
          Fisher's Exact Test
          Chi Square Test
      ab: Background Different types of ventricular arrhythmias (monomorphic ventricular tachycardia [VT], polymorphic VT, or ventricular fibrillation) can be detected by implantable cardiac defibrillators (ICDs) in fast VT zone. The efficacy of antitachycardia pacing (ATP) depends on the type of the treated arrhythmia. We hypothesized that an automatic algorithm based on morphological affinity of ICD far-field electrograms during tachycardia can predict ATP success and the need of shock. Methods The algorithm was evaluated on ventricular arrhythmias recorded in CareLink ICD remote monitoring system (Medtronic Inc., Minneapolis, MN, USA). Patients were selected if first ATP programmed was a burst of eight pulses at 88% coupling interval and if a far-field electrogram was available. The algorithm calculated a stability coefficient (SC) for all their stored ATP-treated fast ventricular arrhythmia (VA) episodes (LC 200-300 ms), analyzing the morphology homogeneity of the last eight recorded far-field electrograms before ventricular arrhythmias detection. Results Inclusion criteria were fulfilled by 717 patients from 29 centers. Three hundred and twenty fast VA were recorded in 103 patients. A higher SC was observed in episodes terminated with the first-ATP (0.78 [0.72-0.84] vs 0.74 [0.60-0.84]; P = 0.006). These differences were especially marked among the 62 episodes of very fast VA (CL ≤250 ms) (0.77 [0.74-0.85] vs 0.64 [0.51-0.8]; P = 0.006). In the multivariate analysis, a SC > 70% was independently associated with a higher likelihood of first-ATP success (odds ratio [OR] = 2.5; [95% confidence interval (CI) = 1.4-4.5], P = 0.001) and a lower need of shock (OR = 0.37; [95% CI = 0.2-0.7], P = 0.002). Conclusion This automatic algorithm (stability coefficient) shows that ATP therapy response can be predicted in fast ventricular arrhythmias through morphology evaluation.
      pubtype: Academic Journal
      doctype:
        algorithm
        equations & formulas
        research
        tables/charts
        tracings
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N