A comparison of automated dispensing cabinet optimization methods.

Purpose. Results of a study comparing two methods of optimizing automated dispensing cabinets (ADCs) are reported. Methods. Eight nonprofiled ADCs were optimized over six months. Optimization of each cabinet involved three steps: (1) removal of medications that had not been dispensed for at least 18...

Descripción completa

Detalles Bibliográficos
Publicado en:American Journal of Health-System Pharmacy Vol. 73; no. 13; pp. 975 - 981
Autores principales: O'Neil, Daniel P., Miller, Adam, Cronin, Daniel, Hatfield, Chad J.
Formato: equations & formulas research tables/charts Journal Article
Publicado: Oxford University Press / USA 7/1/2016
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=116655722&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 116655722
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        10792082
        1X3
      jtl: American Journal of Health-System Pharmacy
      issn: 10792082
      maglogo: N
    pubinfo:
      dt: 7/1/2016
      vid: 73
      iid: 13
      pid: 622
      pub: Oxford University Press / USA
    artinfo:
      ui:
        116655722
        116655722
        116655722
        10.2146/ajhp150423
        116655722
      ppf: 975
      ppct: 6
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: A comparison of automated dispensing cabinet optimization methods.
      aug:
        au:
          O'Neil, Daniel P.
          Miller, Adam
          Cronin, Daniel
          Hatfield, Chad J.
        affil: Department of Pharmacy, West Virginia University Hospitals, Morgantown, WV
      sug:
        subj:
          Drug Administration
          Inventories
          Academic Medical Centers
          Cost Savings
          Human
          Comparative Studies
          Descriptive Statistics
          Data Analysis Software
          Correlation Coefficient
          Funding Source
      ab: Purpose. Results of a study comparing two methods of optimizing automated dispensing cabinets (ADCs) are reported. Methods. Eight nonprofiled ADCs were optimized over six months. Optimization of each cabinet involved three steps: (1) removal of medications that had not been dispensed for at least 180 days, (2) movement of ADC stock to better suit end-user needs and available space, and (3) adjustment of par levels (desired on-hand inventory levels). The par levels of four ADCs (the Day Supply group) were adjusted according to average daily usage; the par levels of the other four ADCs (the Formula group) were adjusted using a standard inventory formula. The primary outcome was the vend:fill ratio, while secondary outcomes included total inventory, inventory cost, quantity of expired medications, and ADC stockout percentage. Results. The total number of medications stocked in the eight machines was reduced from 1,273 in a designated two-month preoptimization period to 1,182 in a designated two-month postoptimization period, yielding a carrying cost savings of $44,981. The mean vend:fill ratios before and after optimization were 4.43 and 4.46, respectively. The vend:fill ratio for ADCs in the Formula group increased from 4.33 before optimization to 5.2 after optimization; in the Day Supply group, the ratio declined (from 4.52 to 3.90). The postoptimization interaction difference between the Formula and Day Supply groups was found to be significant (p = 0.0477). Conclusion. ADC optimization via a standard inventory formula had a positive impact on inventory costs, refills, vend:fill ratios, and stockout percentages.