Variability of FeNO in healthy subjects at 2240 meters above sea level.

Fraction of exhaled nitric oxide (FeNO) is a marker of eosinophilic airway inflammation. Altitude above sea level can affect measurements of this index, but there is only limited information regarding the diurnal variation (ante meridiem vs. post meridiem) and reproducibility of FeNO on consecutive...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Clinical Monitoring & Computing Vol. 30; no. 4; pp. 445 - 450
Autores principales: Gochicoa-Rangel, Laura, Rojas-Cisneros, Fermín, Miguel-Reyes, José, Guerrero-Zúñiga, Selene, Mora-Romero, Uri, Maldonado-Mortera, Ana, Torre-Bouscoulet, Luis, Miguel-Reyes, José Luis, Maldonado-Mortera, Ana Karen
Formato: research tables/charts Journal Article
Publicado: Springer Nature Aug2016
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=117018119&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 117018119
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        13871307
        OHC
      jtl: Journal of Clinical Monitoring & Computing
      issn: 13871307
      maglogo: N
    pubinfo:
      dt: Aug2016
      vid: 30
      iid: 4
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        117018119
        117018119
        NLM26174797
        117018119
        10.1007/s10877-015-9737-0
        NLM26174797
        117018119
      ppf: 445
      ppct: 5
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Variability of FeNO in healthy subjects at 2240 meters above sea level.
      aug:
        au:
          Gochicoa-Rangel, Laura
          Rojas-Cisneros, Fermín
          Miguel-Reyes, José
          Guerrero-Zúñiga, Selene
          Mora-Romero, Uri
          Maldonado-Mortera, Ana
          Torre-Bouscoulet, Luis
          Rojas-Cisneros, Fermín
          Miguel-Reyes, José Luis
          Guerrero-Zúñiga, Selene
          Maldonado-Mortera, Ana Karen
        affil: Departamento de Fisiología Respiratoria, Instituto Nacional de Enfermedades Respiratorias 'Ismael Cosío Villegas', Calzada de Tlalpan 4502, Colonia Sección XVI, Tlalpan C.P. 14080 Mexico City Mexico
      sug:
        subj:
          Altitude
          Nitric Oxide Metabolism
          Male
          Eosinophilia Metabolism
          Female
          Reproducibility of Results
          Cross Sectional Studies
          Asthma Metabolism
          Circadian Rhythm
          Adult
          Research Subjects
          Expiration
          Young Adult
          Human
          Adult: 19-44 years
          Male
          Female
      ab: Fraction of exhaled nitric oxide (FeNO) is a marker of eosinophilic airway inflammation. Altitude above sea level can affect measurements of this index, but there is only limited information regarding the diurnal variation (ante meridiem vs. post meridiem) and reproducibility of FeNO on consecutive days at moderate altitudes. To evaluate the diurnal variability of FeNO and assess its reproducibility over five consecutive days in healthy individuals living at 2240 m, and to compare the FeNO readings taken with two different analyzers. Healthy non-smoking adults were measured using NIOX MINO(®) or NOA 280i(®) devices. One group (n = 10) had readings taken morning and afternoon for five consecutive days with the NIOX MINO(®) equipment; while the second group (n = 17) was measured on only one morning but by both the electrochemical analyzer (NIOX MINO(®)) and the chemiluminescence method (NOA 280i(®)). The study group consisted of 27 subjects aged 28.7 ± 6 years. Morning and afternoon FeNO measurements were 15.2 ± 7.5 ppb and 15.2 ± 7.9 ppb (p = 0.9), respectively. The coefficient of variation (CV) of these measurements (a.m. vs. p.m.) was 10.7 %, and the coefficient of repeatability (CR), 4.2 ppb. The concordance correlation coefficient (CCC) between the two measures (morning vs. afternoon) was 0.91. The CV and CR of the five morning readings were 15.4 % and 4.3 ppb, respectively; while those of the five afternoon measures were 13.6 % and 3.5 ppb, respectively. The CCC between the NIOX MINO(®) equipment and the NOA-280i(®) device was 0.8, with 95 % limits of agreement of -8.35 to 0.29 ppb. In adults living at 2240 m above sea level, FeNO measurements show minimal diurnal variation, and readings are reproducible (<15 %) over a period of at least five consecutive days; however, the FeNO measurements obtained with the NIOX MINO(®) and NOA 280i(®) devices are not interchangeable due to the wide limits of agreement recorded.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N