Effect of Two Work-to-Rest Ratios on Cardiovascular, Thermal, and Perceptual Responses During Fire Suppression and Recovery.

Objective: Fire suppression is a physically demanding occupation that often results in significant heat stress and hypohydration. Guidelines for the number of work intervals allowed before a structured recovery were consensus derived and have not been tested. Methods: Apparently healthy firefighters...

Descripción completa

Detalles Bibliográficos
Publicado en:Prehospital Emergency Care Vol. 20; no. 6; pp. 681 - 688
Autores principales: Hostler, David, Colburn, Deanna, Rittenberger, Jon C., Reis, Steven E.
Formato: research tables/charts Journal Article
Publicado: Taylor & Francis Ltd Nov/Dec2016
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=119150262&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 119150262
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        10903127
        FZB
      jtl: Prehospital Emergency Care
      issn: 10903127
      maglogo: Y
    pubinfo:
      dt: Nov/Dec2016
      vid: 20
      iid: 6
      pid: 377
      pub: Taylor & Francis Ltd
      place: Philadelphia, Pennsylvania
    artinfo:
      ui:
        119150262
        119150262
        119150262
        10.3109/10903127.2016.1168890
        119150262
      ppf: 681
      ppct: 7
      formats:
      tig:
        atl: Effect of Two Work-to-Rest Ratios on Cardiovascular, Thermal, and Perceptual Responses During Fire Suppression and Recovery.
      aug:
        au:
          Hostler, David
          Colburn, Deanna
          Rittenberger, Jon C.
          Reis, Steven E.
      sug:
        subj:
          Work
          Firefighting Adverse Effects
          Research
          Occupational Hazards Prevention and Control
          Human
          Fires Adverse Effects
          Cardiovascular Risk Factors
          Thermography
          Research Subject Recruitment
          Heat Stress Disorders Diagnosis
          Recovery
          Clinical Indicators
          Patient Assessment
      ab: Objective: Fire suppression is a physically demanding occupation that often results in significant heat stress and hypohydration. Guidelines for the number of work intervals allowed before a structured recovery were consensus derived and have not been tested. Methods: Apparently healthy firefighters were recruited for this field study. Subjects were assigned to two or three bouts of live fire training prior to 20 minutes of structured recovery to provide rehydration and cooling. After recovery, the subjects completed a timed test of firefighting skills. Results: Extending the fire suppression interval from two to three work periods before a structured recovery period increased core temperature and the time required to perform a high intensity circuit of firefighting skills immediately following recovery. A mild hypotension was noted during recovery but the groups did not differ for blood pressure, heart rate, or firefighter perception of thermal strain or exertion. Conclusions: This is the first study to examine the physiologic effects of structural firefighting work intervals on recovery and subsequent performance. Both groups experienced maximal cardiovascular strain during fire suppression but extending the work interval worsened heat stress and negatively affected certain aspects of performance immediately following the recovery period.