Open source posturography.
Conclusion: The proposed validation goal of 0.9 in intra-class correlation coefficient was reached with the results of this study. With the obtained results we consider that the developed software (RombergLab) is a validated balance assessment software. The reliability of this software is dependent...
| Published in: | Acta Oto-Laryngologica Vol. 136; no. 12; pp. 1225 - 1230 |
|---|---|
| Main Authors: | , |
| Format: | equations & formulas pictorial research Journal Article |
| Published: |
Taylor & Francis Ltd
Dec2016
|
| Online Access: | View this record in EBSCOhost |
| fields | @attributes: recordID: 1 pdfLink: plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=119450886&site=ehost-live header: @attributes: shortDbName: ccm uiTerm: 119450886 longDbName: CINAHL Complete uiTag: AN controlInfo: bkinfo: dissinfo: jinfo: jid: 00016489 B6D jtl: Acta Oto-Laryngologica issn: 00016489 maglogo: Y pubinfo: dt: Dec2016 vid: 136 iid: 12 pid: 377 pub: Taylor & Francis Ltd place: Philadelphia, Pennsylvania artinfo: ui: 119450886 119450886 119450886 10.1080/00016489.2016.1204665 119450886 ppf: 1225 ppct: 5 formats: fmt: – @attributes: type: T – @attributes: type: P tig: atl: Open source posturography. aug: au: Rey-Martinez, Jorge Pérez-Fernández, Nicolás affil: Otolaryngology Unit Orlgipuzkoa. Clínica Quirón, San Sebastián, Spain sug: subj: Posturography Balance, Postural Pressure Prospective Studies Reproducibility of Results Software Adult Human Physical Therapy Adult: 19-44 years ab: Conclusion: The proposed validation goal of 0.9 in intra-class correlation coefficient was reached with the results of this study. With the obtained results we consider that the developed software (RombergLab) is a validated balance assessment software. The reliability of this software is dependent of the used force platform technical specifications. Objective: Develop and validate a posturography software and share its source code in open source terms. Methods: Prospective non-randomized validation study: 20 consecutive adults underwent two balance assessment tests, six condition posturography was performed using a clinical approved software and force platform and the same conditions were measured using the new developed open source software using a low cost force platform. Intra-class correlation index of the sway area obtained from the center of pressure variations in both devices for the six conditions was the main variable used for validation. Results: Excellent concordance between RombergLab and clinical approved force platform was obtained (intra-class correlation coefficient =0.94). A Bland and Altman graphic concordance plot was also obtained. The source code used to develop RombergLab was published in open source terms. pubtype: Academic Journal doctype: equations & formulas pictorial research Journal Article ougenre: Article language: English refInfo: holdings: @attributes: islocal: N |
|---|