Dynamometry for the measurement of grip, pinch, and trunk muscles strength in subjects with subacute stroke: reliability and different number of trials.

Background: Muscle strength is usually measured in individuals with stroke with Portable dynamometers (gold standard). However, no studies have investigated the reliability, the standard error of measurement (SEM) and the minimal detectable difference (MDD95%) of the dynamometry for the measurement...

Descripción completa

Detalles Bibliográficos
Publicado en:Brazilian Journal of Physical Therapy Vol. 20; no. 5; pp. 395 - 405
Autores principales: Aguiar, Larissa T., Martins, Júlia C., Lara, Eliza M., Albuquerque, Julianna A., Teixeira-Salmela, Luci F., Faria, Christina D. C. M.
Formato: research tables/charts Journal Article
Publicado: Elsevier B.V. Sep/Oct2016
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=119639851&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 119639851
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        14133555
        1FEL
      jtl: Brazilian Journal of Physical Therapy
      issn: 14133555
      maglogo: N
    pubinfo:
      dt: Sep/Oct2016
      vid: 20
      iid: 5
      pid: 82545
      pub: Elsevier B.V.
      place: Philadelphia, Pennsylvania
    artinfo:
      ui:
        119639851
        119639851
        119639851
        10.1590/bjpt-rbf.2014.0173
        119639851
      ppf: 395
      ppct: 10
      formats:
      tig:
        atl: Dynamometry for the measurement of grip, pinch, and trunk muscles strength in subjects with subacute stroke: reliability and different number of trials.
      aug:
        au:
          Aguiar, Larissa T.
          Martins, Júlia C.
          Lara, Eliza M.
          Albuquerque, Julianna A.
          Teixeira-Salmela, Luci F.
          Faria, Christina D. C. M.
        affil: Departamento de Fisioterapia, Escola de Educação Física, Fisioterapia e Terapia Ocupacional, Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG, Brazil
      sug:
        subj:
          Dynamometry
          Grip Strength Evaluation
          Muscle Strength Evaluation
          Stroke Physiopathology
          Portable Equipment
          Equipment Reliability
          Upper Extremity Physiopathology
          Clinical Assessment Tools
          Questionnaires
          Scales
          Validation Studies
          Intrarater Reliability
          Interrater Reliability
          Intraclass Correlation Coefficient
          P-Value
          Reproducibility of Results
          Power Analysis
          Sample Size Determination
          Data Analysis Software
          Descriptive Statistics
          One-Way Analysis of Variance
          Confidence Intervals
          Adult
          Middle Age
          Aged
          Aged, 80 and Over
          Female
          Male
          Human
          Adult: 19-44 years
          Middle Aged: 45-64 years
          Aged: 65+ years
          Aged, 80 & over
          Female
          Male
      ab: Background: Muscle strength is usually measured in individuals with stroke with Portable dynamometers (gold standard). However, no studies have investigated the reliability, the standard error of measurement (SEM) and the minimal detectable difference (MDD95%) of the dynamometry for the measurement of hand grip, pinch grip and trunk strength in subjects with subacute stroke. Objective: 1) To investigate the intra and inter-rater reliability, the SEM and the MDD95% of the portable dynamometers for the measurement of grip, pinch and trunk strength in subjects with subacute stroke, and 2) to verify whether the use of different number of trials (first trial and the average of the first two and three trials) affected the results. Method: 32 subjects with subacute stroke (time since stroke onset: 3.6 months, SD=0.66 months) were evaluated. Hand grip, 3 pinch grips (i.e. pulp-to-pulp/palmar/lateral) and 4 trunk muscles (i.e. flexors, extensors, lateral flexors and rotators) strength were bilaterally assessed (except trunk flexors/extensors) with portable dynamometry by two independent examiners over two sessions (1-2 weeks apart). One-way ANOVAs and intraclass correlation coefficients (ICC2,k) were used for analysis (α=0.05). SEM and MDD95% were also calculated. Results: For all muscular groups and sources of outcome values, including one trial, after familiarization, similar results were found (0.01≤F≤0.08; 0.92≤p≤0.99) with significant and adequate values of intra-rater (0.64≤ICC≤0.99; 0.23≤95%CI≤0.99) and inter-rater (0.66≤ICC≤0.99; 0.25≤95%CI≤0.99) reliability. SEM and MDD95% were considered low (0.39≤EPM≤2.21 Kg; 0.96≤MMD95%<6.12 Kg) for all outcome scores. Conclusion: Only one trial, following familiarization, demonstrated adequate intra-rater and inter-rater reliability of the portable dynamometers for the measurement of hand grip, pinch grip and trunk strength in subjects with subacute stroke.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N