Benchmarking pediatric cranial CT protocols using a dose tracking software system: a multicenter study.

Objectives: To benchmark regional standard practice for paediatric cranial CT-procedures in terms of radiation dose and acquisition parameters.Methods: Paediatric cranial CT-data were retrospectively collected during a 1-year period, in 3 different hospitals of the same country. A dose tracking syst...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 27; no. 2; pp. 841 - 851
Autores principales: De Bondt, Timo, Mulkens, Tom, Zanca, Federica, Pyfferoen, Lotte, Casselman, Jan, Parizel, Paul, Casselman, Jan W, Parizel, Paul M
Formato: research tables/charts Journal Article
Publicado: Springer Nature Feb2017
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=120531438&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 120531438
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: Feb2017
      vid: 27
      iid: 2
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        120531438
        120531438
        NLM27260340
        120531438
        10.1007/s00330-016-4385-4
        NLM27260340
        120531438
      ppf: 841
      ppct: 10
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Benchmarking pediatric cranial CT protocols using a dose tracking software system: a multicenter study.
      aug:
        au:
          De Bondt, Timo
          Mulkens, Tom
          Zanca, Federica
          Pyfferoen, Lotte
          Casselman, Jan
          Parizel, Paul
          Casselman, Jan W
          Parizel, Paul M
        affil: Department of Radiology , Antwerp University Hospital and University of Antwerp , Wilrijkstraat 10 2650 Antwerp Belgium
      sug:
        subj:
          Radiometry Methods
          Benchmarking
          Head
          Tomography, X-Ray Computed Methods
          Software
          Retrospective Design
          Infant
          Cytarabine
          Male
          Pediatrics
          Child, Preschool
          Radiation Dosage
          Purines
          Protocols
          Female
          Child
          Weights and Measures
          Infant, Newborn
          Adolescence
          Human
          Antineoplastic Agents, Combined
          Validation Studies
          Comparative Studies
          Evaluation Research
          Multicenter Studies
          Infant: 1-23 months
          Child, Preschool: 2-5 years
          Child: 6-12 years
          Infant, Newborn: birth-1 month
          Adolescent: 13-18 years
          Male
          Female
      ab: Objectives: To benchmark regional standard practice for paediatric cranial CT-procedures in terms of radiation dose and acquisition parameters.Methods: Paediatric cranial CT-data were retrospectively collected during a 1-year period, in 3 different hospitals of the same country. A dose tracking system was used to automatically gather information. Dose (CTDI and DLP), scan length, amount of retakes and demographic data were stratified by age and clinical indication; appropriate use of child-specific protocols was assessed.Results: In total, 296 paediatric cranial CT-procedures were collected. Although the median dose of each hospital was below national and international diagnostic reference level (DRL) for all age categories, statistically significant (p-value < 0.001) dose differences among hospitals were observed. The hospital with lowest dose levels showed smallest dose variability and used age-stratified protocols for standardizing paediatric head exams. Erroneous selection of adult protocols for children still occurred, mostly in the oldest age-group.Conclusion: Even though all hospitals complied with national and international DRLs, dose tracking and benchmarking showed that further dose optimization and standardization is possible by using age-stratified protocols for paediatric cranial CT. Moreover, having a dose tracking system revealed that adult protocols are still applied for paediatric CT, a practice that must be avoided.Key Points: • Significant differences were observed in the delivered dose between age-groups and hospitals. • Using age-adapted scanning protocols gives a nearly linear dose increase. • Sharing dose-data can be a trigger for hospitals to reduce dose levels.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes: