Comparison of true unenhanced and virtual unenhanced (VUE) attenuation values in abdominopelvic single-source rapid kilovoltage-switching spectral CT.

Objective: To assess the agreement between the true non-contrast (TNC) attenuation values of intra-abdominal structures and attenuation values obtained on virtual-unenhanced (VUE) images based on rapid kVp-switching dual-energy CT. The effects of contrast phase and patient characteristics (e.g., BMI...

Full description

Bibliographic Details
Published in:Abdominal Radiology Vol. 42; no. 3; pp. 710 - 718
Main Authors: Borhani, Amir, Kulzer, Matthew, Iranpour, Negaur, Ghodadra, Anish, Sparrow, Mark, Furlan, Alessandro, Tublin, Mitchell
Format: Journal Article
Published: Springer Nature Mar2017
Online Access:View this record in EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=121882222&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 121882222
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        2366004X
        JT14
      jtl: Abdominal Radiology
      issn: 2366004X
      maglogo: N
    pubinfo:
      dt: Mar2017
      vid: 42
      iid: 3
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        121882222
        143962229
        10.1007/s00261-016-0991-5
        121882222
      ppf: 710
      ppct: 8
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Comparison of true unenhanced and virtual unenhanced (VUE) attenuation values in abdominopelvic single-source rapid kilovoltage-switching spectral CT.
      aug:
        au:
          Borhani, Amir
          Kulzer, Matthew
          Iranpour, Negaur
          Ghodadra, Anish
          Sparrow, Mark
          Furlan, Alessandro
          Tublin, Mitchell
        affil: Division of Abdominal Imaging , University of Pittsburgh School of Medicine, UPMC Presbyterian , Radiology Suite 200 East Wing, 200 Lothrop Street Pittsburgh 15213 USA
      sug:
      ab: Objective: To assess the agreement between the true non-contrast (TNC) attenuation values of intra-abdominal structures and attenuation values obtained on virtual-unenhanced (VUE) images based on rapid kVp-switching dual-energy CT. The effects of contrast phase and patient characteristics (e.g., BMI, hematocrit, hemoglobin content) on VUE values were also investigated. Methods: Ninety four patients who underwent triphasic abdominal CT (liver mass protocol, n = 47; pancreas mass protocol, n = 47) between August 2014 and May 2015 were retrospectively reviewed. Unenhanced series was performed using conventional single-energy mode at 120 kVp. Late arterial and venous phase post-contrast series were obtained utilizing rapid kVp-switching dual-energy CT technique. VUE images were processed off of arterial (VUE-art) and venous (VUE-ven) phase series. Attenuation values of liver, pancreas, kidneys, adrenal glands, muscle, subcutaneous fat, aorta, IVC, and main portal vein were recorded on TNC and VUE sets of images. Attenuation values were compared using univariate linear regression and Student two-tailed paired t test. Results: There was excellent correlation between TNC, VUE-art, and VUE-ven attenuation values across all organs ( p < 0.0001). Paired Student t test, however, showed significant difference between TNC and VUE-art attenuation of kidneys, right adrenal gland, paraspinal muscle, and aorta. There was also significant difference between TNC and VUE-ven attenuation of left kidney. Percentage of cases which had >10 HU difference between VUE and TNC for an individual was calculated which ranged between 13% (right kidney) and 42% (right adrenal gland). Conclusion: Although the correlation between VUE and TNC attenuation values was excellent and mean difference between TNC and VUE attenuation values was negligible (ranging between −5.94 HU for paraspinal muscles to 6.2 HU in aorta), intra-patient analysis showed a considerable number of cases which had >10 HU difference between VUE and TNC. VUE-ven generally offered a better approximation of TNC values. Further optimization of post-processing algorithms might be necessary before complete replacement of TNC with VUE images.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N