Time Required to Rectify Inhaler Errors Among Experienced Subjects With Faulty Technique.

BACKGROUND: Regardless of the device used, many patients have difficulty maintaining proper inhaler technique over time. Repeated education from caregivers is required to ensure persistence of correct inhaler technique, but no information is available to evaluate the time required to rectify inhaler...

Descripción completa

Detalles Bibliográficos
Publicado en:Respiratory Care Vol. 62; no. 4; pp. 409 - 415
Autores principales: Melani, Andrea S., Bonavia, Marco, Mastropasqua, Eliuccia, Zanforlin, Alessandro, Lodi, Marco, Martucci, Paola, Scichilone, Nicola, Aliani, Maria, Neri, Margherita, Sestini, Piersante
Formato: CEU research tables/charts Journal Article
Publicado: Mary Ann Liebert, Inc. Apr2017
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=122250252&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 122250252
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        00201324
        4GG
      jtl: Respiratory Care
      issn: 00201324
      maglogo: N
    pubinfo:
      dt: Apr2017
      vid: 62
      iid: 4
      pid: 1365
      pub: Mary Ann Liebert, Inc.
      place: New Rochelle, New York
    artinfo:
      ui:
        122250252
        122250252
        122250252
        10.4187/respcare.05117
        122250252
      ppf: 409
      ppct: 6
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Time Required to Rectify Inhaler Errors Among Experienced Subjects With Faulty Technique.
      aug:
        au:
          Melani, Andrea S.
          Bonavia, Marco
          Mastropasqua, Eliuccia
          Zanforlin, Alessandro
          Lodi, Marco
          Martucci, Paola
          Scichilone, Nicola
          Aliani, Maria
          Neri, Margherita
          Sestini, Piersante
        affil: Fisiopatologia e Riabilitazione Respiratoria, Policlinico Le Scotte, Azienda Ospedaliera Universitaria Senese, Siena, Italy
      sug:
        subj:
          Nebulizers and Vaporizers Utilization
          Medication Errors
          Patient Education
          Human
          Cross Sectional Studies
          Descriptive Statistics
          Data Analysis Software
          Confidence Intervals
          Pulmonary Disease, Chronic Obstructive
          Observational Methods
          Caregivers
          Asthma
          Male
          Female
          Middle Age
          Aged
          Time Factors
          Education, Continuing (Credit)
          Middle Aged: 45-64 years
          Aged: 65+ years
          Male
          Female
      ab: BACKGROUND: Regardless of the device used, many patients have difficulty maintaining proper inhaler technique over time. Repeated education from caregivers is required to ensure persistence of correct inhaler technique, but no information is available to evaluate the time required to rectify inhaler errors in experienced users with a baseline faulty technique and whether this time of re-education to restore inhaler mastery can differ between devices. METHODS: This was a multicenter, single-visit, open-label, cross-sectional study in a large group of 981 adult subjects (mean ± SD age 64 ± 15 y) experienced with inhaler use, mainly suffering from COPD and asthma, who showed faulty inhaler technique at a follow-up visit in chest clinics. These subjects received face-to-face practical education from trained caregivers until proper inhaler use could be demonstrated, and the time of instruction was recorded. RESULTS: The mean times (95% CIs) in minutes of instruction required for rectifying misuse and demonstrating inhaler mastery were 5.0 (3.6-6.4) min for the Diskus (n = 199), 5.3 (3.7-6.8) min for the HandiHaler (n = 219), 8.1 (5.6-10.5) min for the metered-dose inhaler (MDI) (n = 532), and 6.0 (5.0-7.0) min for the Turbuhaler (n = 169). The time to demonstrate good inhaler use for MDIs was higher (P < .05) than for all dry powder inhalers (DPIs). Between the DPIs, only the HandiHaler required more time for achieving mastery than the Diskus (P = .005). The variables associated with increasing time for correcting inhaler errors were an older age (0.05 min/y, 95% CI 0.03-0.07), a lower level of education (0.4 min/ schooling level, 95% CI 0.7-0.1), and no reported previous instruction in inhaler use (1.96 min, 95% CI 1.35-2.58). CONCLUSIONS: In experienced subjects with baseline faulty inhaler use, the mean time of education required to achieve and demonstrate mastery with DPIs was lower than with MDIs.