In vivo comparison of two navigation systems for abdominal percutaneous needle intervention.

Purpose: To compare the accuracy of a Kinect-Optical navigation system with an electromagnetic (EM) navigation system for percutaneous liver needle intervention. Materials and methods: Five beagles with nine artificial tumors were used for validation. The Veran IG4 EM navigation system and a custom-...

Descripción completa

Detalles Bibliográficos
Publicado en:Abdominal Radiology Vol. 42; no. 7; pp. 1993 - 2001
Autores principales: Xiao, Deqiang, Li, Yong, Luo, Huoling, Zhang, Yanfang, Guo, Xuejun, Zheng, Huimin, Hu, Qingmao, Jia, Fucang
Formato: Journal Article
Publicado: Springer Nature Jul2017
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=123716801&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 123716801
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        2366004X
        JT14
      jtl: Abdominal Radiology
      issn: 2366004X
      maglogo: N
    pubinfo:
      dt: Jul2017
      vid: 42
      iid: 7
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        123716801
        144101451
        10.1007/s00261-017-1083-x
        123716801
      ppf: 1993
      ppct: 8
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: In vivo comparison of two navigation systems for abdominal percutaneous needle intervention.
      aug:
        au:
          Xiao, Deqiang
          Li, Yong
          Luo, Huoling
          Zhang, Yanfang
          Guo, Xuejun
          Zheng, Huimin
          Hu, Qingmao
          Jia, Fucang
        affil: Department of Interventional Radiology , Shenzhen People's Hospital , No. 1017, Dongmen North Rd., Luohu Shenzhen China
      sug:
      ab: Purpose: To compare the accuracy of a Kinect-Optical navigation system with an electromagnetic (EM) navigation system for percutaneous liver needle intervention. Materials and methods: Five beagles with nine artificial tumors were used for validation. The Veran IG4 EM navigation system and a custom-made Kinect-Optical navigation system were used. Needle insertions into each tumor were conducted with these two guidance methods. The target positioning error (TPE) and the time cost of the puncture procedures were evaluated. Results: A total of 18 needle insertions were performed to evaluate the navigation accuracy of the two guidance approaches. The targeting error was 6.78 ± 3.22 mm and 8.72 ± 3.5 mm for the Kinect-Optical navigation system and the EM navigation system, respectively. There is no statistically significant difference in the TPE between the Kinect-Optical navigation system and the EM navigation system ( p = 0.229). The processing time with the Kinect-Optical system (10 min) is similar to that of the Veran IG4 system (12 min). Conclusions: The accuracy of the Kinect-Optical navigation system is comparable to that of the EM navigation system.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N