Multiparametric dynamic contrast-enhanced ultrasound imaging of prostate cancer.

Objectives: The aim of this study is to improve the accuracy of dynamic contrast-enhanced ultrasound (DCE-US) for prostate cancer (PCa) localization by means of a multiparametric approach.Materials and Methods: Thirteen different parameters related to either perfusion or dispersion were extracted pi...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 27; no. 8; pp. 3226 - 3235
Autores principales: Wildeboer, Rogier, Postema, Arnoud, Demi, Libertario, Kuenen, Maarten, Wijkstra, Hessel, Mischi, Massimo, Wildeboer, Rogier R, Postema, Arnoud W, Kuenen, Maarten P J
Formato: diagnostic images research tables/charts Journal Article
Publicado: Springer Nature Aug2017
Acceso en línea:Ver este registro en EBSCOhost
Descripción
Sumario:Objectives: The aim of this study is to improve the accuracy of dynamic contrast-enhanced ultrasound (DCE-US) for prostate cancer (PCa) localization by means of a multiparametric approach.Materials and Methods: Thirteen different parameters related to either perfusion or dispersion were extracted pixel-by-pixel from 45 DCE-US recordings in 19 patients referred for radical prostatectomy. Multiparametric maps were retrospectively produced using a Gaussian mixture model algorithm. These were subsequently evaluated on their pixel-wise performance in classifying 43 benign and 42 malignant histopathologically confirmed regions of interest, using a prostate-based leave-one-out procedure.Results: The combination of the spatiotemporal correlation (r), mean transit time (μ), curve skewness (κ), and peak time (PT) yielded an accuracy of 81% ± 11%, which was higher than the best performing single parameters: r (73%), μ (72%), and wash-in time (72%). The negative predictive value increased to 83% ± 16% from 70%, 69% and 67%, respectively. Pixel inclusion based on the confidence level boosted these measures to 90% with half of the pixels excluded, but without disregarding any prostate or region.Conclusions: Our results suggest multiparametric DCE-US analysis might be a useful diagnostic tool for PCa, possibly supporting future targeting of biopsies or therapy. Application in other types of cancer can also be foreseen.Key Points: • DCE-US can be used to extract both perfusion and dispersion-related parameters. • Multiparametric DCE-US performs better in detecting PCa than single-parametric DCE-US. • Multiparametric DCE-US might become a useful tool for PCa localization.