OPTICAL FEEDBACK INTERFEROMETRY: FROM BASICS TO APPLICATIONS OF LASER FLOWMETRY.

Optical feedback interferometry (OFI) is a contactless technique that is employed for measuring parameters related to object's motion. The light emitted by a laser is backreflected or scattered from a moving object and a small portion of the scattered waves re-enters the laser cavity and impacts the...

Descripción completa

Detalles Bibliográficos
Publicado en:Revista Cubana de Física Vol. 34; no. 1; pp. 48 - 58
Autores principales: RAMÍREZ-MIQUET, E. E., PERCHOUX, J., DA COSTA-MOREIRA, R., ZHAO, Y., LUNA-ARRIAGA, A., TRONCHE, C., SOTOLONGO-COSTA, O.
Formato: Artículo
Publicado: Universidad de La Habana 2017
Materias:
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=lth&AN=124257192&site=ehost-live
header:
  @attributes:
    shortDbName: lth
    uiTerm: 124257192
    longDbName: MedicLatina
    uiTag: AN
  controlInfo:
    bkinfo:
    jinfo:
      jid:
        02539268
        UEW
      jtl: Revista Cubana de Física
      issn: 02539268
      maglogo: N
    pubinfo:
      dt: 2017
      vid: 34
      iid: 1
      pid: 21208
      pub: Universidad de La Habana
    artinfo:
      ui: 124257192
      ppf: 48
      ppct: 10
      formats:
        fmt:
          @attributes:
            type: P
            size: 2.7MB
      tig:
        atl: OPTICAL FEEDBACK INTERFEROMETRY: FROM BASICS TO APPLICATIONS OF LASER FLOWMETRY.
      aug:
        au:
          RAMÍREZ-MIQUET, E. E.
          PERCHOUX, J.
          DA COSTA-MOREIRA, R.
          ZHAO, Y.
          LUNA-ARRIAGA, A.
          TRONCHE, C.
          SOTOLONGO-COSTA, O.
        affil:
          LAAS-CNRS, Université de Toulouse, CNRS, INR Toulouse F-31000, France
          Centro de Aplicaciones Tecnológicas y Desarrollo Nuclear. Calle 30, No. 502, Miramar CP. 11300, La Habana, Cuba
          Laboratoire Matériaux et Phénomènes Quantiques, Université Paris Diderot, CNRS, Sorbonne Paris Cité, UMR, 7162, 10 rue Alice Dom on et Léonie Duquet, Paris 75013, France
          IICBA, ClnC, Universidad Autónoma del Estado de Morelos, Avenida Universidad 1001, Cuernavaca, CP 62209 Morelos, Mexico
      su:
        Interferometry
        Laser Doppler velocimeter
        Microfluidics
        Particle detectors
        Perfusion
        Flow measurement
      sug:
        subj:
          Interferometry
          Laser Doppler velocimeter
          Microfluidics
          Particle detectors
          Perfusion
          Flow measurement
      ab:
        Optical feedback interferometry (OFI) is a contactless technique that is employed for measuring parameters related to object's motion. The light emitted by a laser is backreflected or scattered from a moving object and a small portion of the scattered waves re-enters the laser cavity and impacts the laser's emission properties. We review the theoretical basics of optical feedback interferometry and explain the physical principles in the frame of laser Doppler flowmetry. We present a model derived from the Lang and Kobayashi rate equations to show the particular features of the optical feedback signal in temporal and frequency domain. In addition, we present experimental measurements relative to the detection of flowing particles in a microchannel, the measurement of unsteady flows and the quantification of blood perfusion in skin, which demonstrate the potential use of OFI sensors in the assessment of fluidic systems of interest in chemical and biomedical engineering.
        La interferometría de retroinyección óptica (IRO) constituye una técnica de no contacto utilizada para la medición de parámetros del movimiento. La luz emitida por un láser es esparcida por un objeto en movimiento y una pequeña parte de las ondas producto de esa dispersión entran en la cavidad del láser, impactando sus propiedades espectrales. Se presenta una revisión de las bases teóricas del efecto de la retroinyección óptica y se exponen sus principios físicos en el marco de la flujometría. Se presenta un modelo derivado de las ecuaciones de Lang y Kobayashi para mostrar las características principales de la señal de retroinyección óptica en dominio temporal y frecuencial. Adicionalmente, se presentan resultados experimentales relativos a la medición de partículas fluyendo dentro de un microcanal, la medición de flujos no estacionarios y la cuantificación de la perfusión sanguínea en la piel, los cuales demuestran los usos potenciales de los sensores IRO para el análisis de sistemas fluídicos de interés para la ingeniería química y biomédica.
      pubtype: Academic Journal
      doctype: Article
      src: R
    language: English
    refInfo:
    copyright:
      @attributes:
        flag: Y
      custom: Copyright of Revista Cubana de Física is the property of Universidad de La Habana and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use.
      item: Revista Cubana de Física
      holder: Universidad de La Habana
      dt:
        @attributes:
          year: 2017
    holdings:
      @attributes:
        islocal: N