Repeated intravenous administration of gadobutrol does not lead to increased signal intensity on unenhanced T1-weighted images-a voxel-based whole brain analysis.

Objectives: To identify a possible association between repeated intravenous administration of gadobutrol and increased signal intensity in the grey and white matter using voxel-based whole-brain analysis.Methods: In this retrospective single-centre study, 217 patients with a clinically isolated synd...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 27; no. 9; pp. 3687 - 3694
Autores principales: Langner, Soenke, Kromrey, Marie-Luise, Kuehn, Jens-Peter, Grothe, Matthias, Domin, Martin
Formato: research tables/charts Journal Article
Publicado: Springer Nature Sep2017
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=124485402&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 124485402
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: Sep2017
      vid: 27
      iid: 9
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        124485402
        124485402
        144097120
        NLM28289935
        124485402
        10.1007/s00330-017-4777-0
        NLM28289935
        124485402
      ppf: 3687
      ppct: 7
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Repeated intravenous administration of gadobutrol does not lead to increased signal intensity on unenhanced T1-weighted images-a voxel-based whole brain analysis.
      aug:
        au:
          Langner, Soenke
          Kromrey, Marie-Luise
          Kuehn, Jens-Peter
          Grothe, Matthias
          Domin, Martin
        affil: Institute of Diagnostic Radiology and Neuroradiology , University Medicine Greifswald , Ferdinand-Sauerbruch-Straße 17475 Greifswald Germany
      sug:
        subj:
          Contrast Media Administration and Dosage
          Brain Diseases
          Magnetic Resonance Imaging Methods
          Organometallic Compounds Administration and Dosage
          Male
          Brain
          Aged
          Female
          Adult
          Gray Matter
          Administration, Intravenous
          Middle Age
          Retrospective Design
          Cerebellum Pathology
          Human
          Aged: 65+ years
          Adult: 19-44 years
          Middle Aged: 45-64 years
          Male
          Female
      ab: Objectives: To identify a possible association between repeated intravenous administration of gadobutrol and increased signal intensity in the grey and white matter using voxel-based whole-brain analysis.Methods: In this retrospective single-centre study, 217 patients with a clinically isolated syndrome underwent baseline brain magnetic resonance imaging and at least one annual follow-up examination with intravenous administration of 0.1 mmol/kg body weight of gadobutrol. Using the "Diffeomorphic Anatomical Registration using Exponentiated Lie algebra" (DARTEL) normalisation process, tissue templates for grey matter (GM), white matter (WM), and cerebrospinal fluid (CSF) were calculated, as were GM-CSF and WM-CSF ratios. Voxel-based whole-brain analysis was used to calculate the signal intensity for each voxel in each data set. Paired t-test was applied to test differences to baseline MRI for significance.Results: Voxel-based whole-brain analysis demonstrated no significant changes in signal intensity of grey and white matter after up to five gadobutrol administrations. There was no significant change in GM-CSF and grey WM-CSF ratios.Conclusion: Voxel-based whole-brain analysis did not demonstrate increased signal intensity of GM and WM on unenhanced T1-weighted images after repeated gadobutrol administration. The molecular structure of gadolinium-based contrast agent preparations may be an essential factor causing SI increase on unenhanced T1-weighted images.Key Points: • Repeated administration of gadobutrol does not lead to increased signal intensity. • Voxel-based whole-brain analysis allows assessment of subtle changes in signal intensity. • Macrocyclic contrast agents in a proven dosage are safe.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N