Detection of exercise periodic breathing using thermal flowmeter in patients with heart failure.

Exercise periodic breathing (EPB) is associated with exercise intolerance and poor prognosis in patients with heart failure (HF). However, EPB detection during cardiopulmonary exercise test (CPET) is difficult. The present study investigated the use of a wireless monitoring device to record the EPB...

Descripción completa

Detalles Bibliográficos
Publicado en:Medical & Biological Engineering & Computing Vol. 55; no. 8; pp. 1189 - 1199
Autores principales: Fu, Tieh-Cheng, Lin, Wen-Chen, Wang, Jong-Shyan, Wang, Chao-Hung, Chang, Chun-Tien, Tsai, Cheng-Lun, Lee, Yun-Shien, Lin, Kang-Ping
Formato: pictorial research tables/charts Journal Article
Publicado: Springer Nature Aug2017
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=124485694&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 124485694
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01400118
        PO0
      jtl: Medical & Biological Engineering & Computing
      issn: 01400118
      maglogo: N
    pubinfo:
      dt: Aug2017
      vid: 55
      iid: 8
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        124485694
        124485694
        144106600
        NLM27744563
        124485694
        10.1007/s11517-016-1581-y
        NLM27744563
        124485694
      ppf: 1189
      ppct: 10
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Detection of exercise periodic breathing using thermal flowmeter in patients with heart failure.
      aug:
        au:
          Fu, Tieh-Cheng
          Lin, Wen-Chen
          Wang, Jong-Shyan
          Wang, Chao-Hung
          Chang, Chun-Tien
          Tsai, Cheng-Lun
          Lee, Yun-Shien
          Lin, Kang-Ping
        affil: Technology Translation Center for Medical Device , Chung Yuan Christian University , Tao-Yuan Taiwan
      sug:
        subj:
          Heart Failure Diagnosis
          Exercise Test Equipment and Supplies
          Breath Tests Equipment and Supplies
          Respiration Disorders Diagnosis
          Respiration Disorders Physiopathology
          Thermography Equipment and Supplies
          Heart Failure Physiopathology
          Equipment Failure
          Middle Age
          Male
          Rheology Equipment and Supplies
          Respiratory Mechanics
          Reproducibility of Results
          Diagnosis, Computer Assisted Methods
          Female
          Heart Failure Complications
          Sensitivity and Specificity
          Equipment Design
          Respiration Disorders Etiology
          Physics Equipment and Supplies
          Human
          Middle Aged: 45-64 years
          Male
          Female
      ab: Exercise periodic breathing (EPB) is associated with exercise intolerance and poor prognosis in patients with heart failure (HF). However, EPB detection during cardiopulmonary exercise test (CPET) is difficult. The present study investigated the use of a wireless monitoring device to record the EPB during CPET and proposed quantization parameter estimates for the EPB. A total of 445 patients with HF were enrolled and underwent exercise tests. The ventilation data from the wearable device were compared with the data obtained during the CPET and were analyzed based on professional opinion and on 2 automated programs (decision tree [DT] and oscillatory pattern methods). The measurement accuracy was greater with the DT method (89 %) than with the oscillatory pattern method (75 %). The cutoffs for EPB recognition using the DT method were (1) an intercept of the regression line passing through the minute ventilation rate vs. the time curve during the recovery phase ≥64.63, and (2) an oscillatory phase duration to total exercise time ratio ≥0.5828. The wearable device was suitable for the assessment of EPB in patients with HF, and our new automated analysis system using the DT method effectively identified the EPB pattern.
      pubtype: Academic Journal
      doctype:
        pictorial
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N