Accuracy of bone mineral density quantification using dual-layer spectral detector CT: a phantom study.

Objectives: To investigate the accuracy of bone mineral density (BMD) quantification using dual-layer spectral detector CT (SDCT) at various scan protocols.Methods: Two validated anthropomorphic phantoms containing inserts of 50-200 mg/cm3 calcium hydroxyapatite (HA) were scanned using a 64-slice SD...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 27; no. 10; pp. 4351 - 4360
Autores principales: Hamersvelt, Robbert, Schilham, Arnold, Engelke, Klaus, Harder, Annemarie, Keizer, Bart, Verhaar, Harald, Leiner, Tim, Jong, Pim, Willemink, Martin, van Hamersvelt, Robbert W, Schilham, Arnold M R, den Harder, Annemarie M, de Keizer, Bart, Verhaar, Harald J, de Jong, Pim A, Willemink, Martin J
Formato: Journal Article
Publicado: Springer Nature Oct2017
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=124912461&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 124912461
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: Oct2017
      vid: 27
      iid: 10
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        124912461
        124912461
        144086695
        NLM28374079
        10.1007/s00330-017-4801-4
        NLM28374079
        124912461
      ppf: 4351
      ppct: 9
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Accuracy of bone mineral density quantification using dual-layer spectral detector CT: a phantom study.
      aug:
        au:
          Hamersvelt, Robbert
          Schilham, Arnold
          Engelke, Klaus
          Harder, Annemarie
          Keizer, Bart
          Verhaar, Harald
          Leiner, Tim
          Jong, Pim
          Willemink, Martin
          van Hamersvelt, Robbert W
          Schilham, Arnold M R
          den Harder, Annemarie M
          de Keizer, Bart
          Verhaar, Harald J
          de Jong, Pim A
          Willemink, Martin J
        affil: Department of Radiology , University Medical Centre Utrecht , 3508 GA Utrecht The Netherlands
      sug:
        subj:
          Tomography, X-Ray Computed Methods
          Bone Density
          Phantoms, Imaging
          Osteoporosis
          Absorptiometry, Photon
          Scales
      ab: Objectives: To investigate the accuracy of bone mineral density (BMD) quantification using dual-layer spectral detector CT (SDCT) at various scan protocols.Methods: Two validated anthropomorphic phantoms containing inserts of 50-200 mg/cm3 calcium hydroxyapatite (HA) were scanned using a 64-slice SDCT scanner at various acquisition protocols (120 and 140 kVp, and 50, 100 and 200 mAs). Regions of interest (ROIs) were placed in each insert and mean attenuation profiles at monochromatic energy levels (90-200 keV) were constructed. These profiles were fitted to attenuation profiles of pure HA and water to calculate HA concentrations. For comparison, one phantom was scanned using dual energy X-ray absorptiometry (DXA).Results: At both 120 and 140 kVp, excellent correlations (R = 0.97, P < 0.001) were found between true and measured HA concentrations. Mean error for all measurements at 120 kVp was -5.6 ± 5.7 mg/cm3 (-3.6 ± 3.2%) and at 140 kVp -2.4 ± 3.7 mg/cm3 (-0.8 ± 2.8%). Mean measurement errors were smaller than 6% for all acquisition protocols. Strong linear correlations (R2 ≥ 0.970, P < 0.001) with DXA were found.Conclusions: SDCT allows for accurate BMD quantification and potentially opens up the possibility for osteoporosis evaluation and opportunistic screening in patients undergoing SDCT for other clinical indications. However, patient studies are needed to extend and translate our findings.Key Points: • Dual-layer spectral detector CT allows for accurate bone mineral density quantification. • BMD measurements on SDCT are strongly linearly correlated to DXA. • SDCT, acquired for several indications, may allow for evaluation of osteoporosis. • This potentially opens up the possibility for opportunistic osteoporosis screening.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N