Test-retest reliability of echo intensity parameters in healthy Achilles tendons using a semi-automatic tracing procedure.

Objective: To evaluate the test-retest reliability of the ultrasound echo intensity parameters on healthy Achilles tendon using a semi-automatic tracing procedure.Materials and Methods: Eighteen healthy volunteers participated. B-mode images were acquired in the transverse plane (mid-tendon; inserti...

Descripción completa

Detalles Bibliográficos
Publicado en:Skeletal Radiology Vol. 46; no. 11; pp. 1553 - 1559
Autores principales: Schneebeli, Alessandro, Del Grande, Filippo, Vincenzo, Gabriele, Cescon, Corrado, Barbero, Marco
Formato: Journal Article
Publicado: Springer Nature Nov2017
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=125148417&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 125148417
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        03642348
        O14
      jtl: Skeletal Radiology
      issn: 03642348
      maglogo: N
    pubinfo:
      dt: Nov2017
      vid: 46
      iid: 11
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        125148417
        125148417
        143979337
        NLM28828624
        10.1007/s00256-017-2748-9
        NLM28828624
        125148417
      ppf: 1553
      ppct: 6
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Test-retest reliability of echo intensity parameters in healthy Achilles tendons using a semi-automatic tracing procedure.
      aug:
        au:
          Schneebeli, Alessandro
          Del Grande, Filippo
          Vincenzo, Gabriele
          Cescon, Corrado
          Barbero, Marco
        affil: Rehabilitation Research Laboratory 2rLab, Department of Business Economics, Health and Social Care , University of Applied Sciences and Arts of Southern Switzerland , Stabile piazzetta, Via violino, 6928 Manno Switzerland
      sug:
        subj:
          Ultrasonography Methods
          Achilles Tendon
          Reference Values
          Male
          Young Adult
          Reproducibility of Results
          Research Subjects
          Female
          Male
          Female
      ab: Objective: To evaluate the test-retest reliability of the ultrasound echo intensity parameters on healthy Achilles tendon using a semi-automatic tracing procedure.Materials and Methods: Eighteen healthy volunteers participated. B-mode images were acquired in the transverse plane (mid-tendon; insertion) and used to analyze tendon echogenicity. Grayscale distribution of the pixels within the selected ROIs was represented as a histogram. Descriptive statistics of the grayscale distribution (mean, variance, skewness, kurtosis, and entropy) and parameters from the co-occurrence matrix (contrast, energy, and homogeneity) were calculated.Results: Reliability of echo intensity parameters of the mid-Achilles tendon ranged from high to very high with an ICC2.k of 0.94 for echogenicity, 0.87 for variance, 0.80 for skewness, 0.72 for kurtosis, 0.89 for entropy, 0.90 for contrast, 0.91 for energy, and 0.93 for homogeneity, while for tendon insertion they ranged from moderate to high with an ICC2.k of 0.74 for echogenicity, 0.88 for variance, 0.75 for skewness, 0.55 for kurtosis, 0.87 for entropy, 0.70 for contrast, 0.77 for energy, and 0.56 for homogeneity.Conclusion: Ultrasound echo intensity is a reliable technique to characterize the internal structure of the Achilles tendon.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N