Homogenous scaffold-based cranial/skull implant modelling and structural analysis-unit cell algorithm-meshless approach.

This computational study explores a unique modelling approach of the cranial implant, homogenous scaffold algorithm and meshless method, respectively. This meshless method is employed to review the implant underneath intracranial pressure (ICP) conditions with a standard ICP range of 7 mm of Hg to 1...

Full description

Bibliographic Details
Published in:Medical & Biological Engineering & Computing Vol. 55; no. 11; pp. 2053 - 2066
Main Authors: Phanindra Bogu, V, Ravi Kumar, Y, Kumar Khanra, Asit
Format: pictorial research tables/charts Journal Article
Published: Springer Nature Nov2017
Online Access:View this record in EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=125728365&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 125728365
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01400118
        PO0
      jtl: Medical & Biological Engineering & Computing
      issn: 01400118
      maglogo: N
    pubinfo:
      dt: Nov2017
      vid: 55
      iid: 11
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        125728365
        125728365
        144182254
        NLM28474182
        125728365
        10.1007/s11517-017-1649-3
        NLM28474182
        125728365
      ppf: 2053
      ppct: 13
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Homogenous scaffold-based cranial/skull implant modelling and structural analysis-unit cell algorithm-meshless approach.
      aug:
        au:
          Phanindra Bogu, V
          Ravi Kumar, Y
          Kumar Khanra, Asit
        affil: Department of Mechanical Engineering , National Institute of Technology Warangal , Warangal 506004 India
      sug:
        subj:
          Skull Physiopathology
          Skull Surgery
          Software
          Titanium
          Physics
          Materials Testing Methods
          Prostheses and Implants
          Finite Element Analysis
          Algorithms
          Ketones
          Osseointegration Drug Effects
          Polyethylene Glycols
          Human
      ab: This computational study explores a unique modelling approach of the cranial implant, homogenous scaffold algorithm and meshless method, respectively. This meshless method is employed to review the implant underneath intracranial pressure (ICP) conditions with a standard ICP range of 7 mm of Hg to 15 mm of Hg. The algorithm is used to introduce uniform porosity within the implant enabling the implant behaviour with respect to ICP conditions. However, increase in the porosity leads to variation in deformation and equivalent stress, respectively. The meshless approach provides a valuable insight in order to know the effect of total deformation and equivalent stress (von Mises stress) and replaces the standard meshing strategies. The patient CT data (computed tomography) is processed in MIMICS software to get the mesh model. An entirely unique modelling approach is developed to model the cranial implant with the assistance of the Rhinoceros software. This modelling methodology is the easiest one and addressing both the symmetrical and asymmetrical defects. The implant is embedded in a unit cell-based porous structure with the help of an algorithm, and this algorithm is simple to manage the consistency in porosity and pore size of the scaffold. Totally six types of implants are modelled with variation in porosity and replicate the original cranial bone. Among six implants, Type 2 (porosity 82.62%) and Type 5 (porosity 45.73%) implants are analysed with the meshless approach under ICP. The total deformation and equivalent stress (von Mises stress) of porous implants are compared with the solid implant under same ICP conditions. Consequently, distinctive materials are used for structural analysis such as titanium alloy (Ti6Al4V) and polyether-ether-ketone (PEEK), respectively. The deformation and equivalent stress (von Mises stress) results are obtained through the structural analysis. It was observed from the results that the titanium-based solid implant is the best implant in all aspects, while considering weight and osseointegration PEEK-based Type 5 implant is the best one. A novel free-form closed curve network (FCN) technique is successfully developed to model a cranial implant for symmetrical and asymmetrical defects. The porous implant is adequately modelled through the unit cell algorithm and analysed through meshless approach. The implementation of 3D printed component will allow physicians to gain knowledge and successfully plan the preoperative surgery.
      pubtype: Academic Journal
      doctype:
        pictorial
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N